TABLE III. Group A inspection for device type 02 - Continued. 11
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,B,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Case C |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Min |
Max |
|||||
Test no. |
Clock 1 |
Clear 1 |
K1 |
vCC |
Clock 2 |
Clear 2 |
J2 |
Q2 |
Q2 |
K2 |
GND |
Q1 |
Q1 |
J1 |
|||||||
10 TC=+125°C |
fMAX |
(Fig. 6) |
86 87 88 89 |
IN IN |
2.4 v 2.4 v |
5.0 v " " " |
IN IN |
2.4 v 2.4 v |
OUT |
OUT |
2.4 v 2.4 v |
GND " " " |
OUT |
OUT |
2.4 v 2.4 v |
Q1 Q1 Q2 Q2 |
20 " " " |
MHz " " " |
|||
tPLH1 |
3003 (Fig. 5) |
90 91 |
IN |
IN |
GND |
" " |
IN |
IN |
2.4 v |
OUT |
GND |
" " |
OUT |
2.4 v |
Clear 1 to Q1 Clear 2 to Q2 |
2 " |
20 20 |
ns " |
|||
tPHL1 |
92 93 |
IN |
IN |
GND |
" " |
IN |
IN |
2.4 v |
OUT |
GND |
" " |
OUT |
2.4 v |
Clear 1 to Q1 Clear 2 to Q2 |
" " |
31 31 |
" " |
||||
tPLH2 |
3003 (Fig. 6) |
94 95 96 97 |
IN IN |
2.4 v 2.4 v |
" " " " |
IN IN |
2.4 v 2.4 v |
OUT |
OUT |
2.4 v 2.4 v |
" " " " |
OUT |
OUT |
2.4 v 2.4 v |
Clock 1 to Q1 Clock 1 to Q1 Clock 2 to Q2 Clock 2 to Q2 |
" " " " |
35 " " " |
" " " " |
|||
tPHL2 |
98 99 100 101 |
IN IN |
2.4 v 2.4 v |
" " " " |
IN IN |
2.4 v 2.4 v |
OUT |
OUT |
2.4 v 2.4 v |
" " " " |
OUT |
OUT |
2.4 v 2.4 v |
Clock 1 to Q1 Clock 1 to Q1 Clock 2 to Q2 Clock 2 to Q2 |
" " " " |
42 " " " |
" " " " |
||||
11 |
Same tests, terminal conditions, and limits as subgroup 10, except TC = -55°C. |
A = Normal clock pulse.
B = Momentary GND, then 4.5 v. D = Momentary 4.5 v, then GND.
E = Momentary GND, then 2.4 v.
F = Momentary GND, then 5.5 v.
* = Test time limit � 100 ns.
11 Terminal conditions (pins not designated may be H � 2.0 v, or L ≤ 0.8 v, or open).
21 Input shall be one normal clock pulse, then 4.5 v.
31 Tests shall be performed in sequence.
41 Input voltages shown are: A = 2.0 v minimum and B = 0.8 v maximum.
51 Output voltages shall be either: H = 2.4 v, minimum and L = 0.4 v, maximum when using a high speed checker double comparator, or H � 1.5 v and L ≤ 1.5 v when using a high speed checker single comparator.