TABLE III. Group A inspection for device type 03 - Continued. 11
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,B,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Case C |
3 |
2 |
1 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
5 |
4 |
Min |
Max |
|||||
Test no. |
Clock 1 |
D1 |
Clear 1 |
VCC |
Clear 2 |
D2 |
Clock 2 |
Preset 2 |
Q2 |
Q2 |
GND |
Q1 |
Q1 |
Preset 1 |
|||||||
1 TC=+25°C |
IOS |
3011 |
49 50 51 52 |
GND |
5.5 V " " " |
GND |
GND |
GND |
GND |
GND " " " |
GND |
GND |
GND |
Q1 Q1 Q2 Q2 |
-40 " " " |
-100 " " " |
mA " " " |
||||
ICC |
3005 |
53 54 |
GND GND |
GND GND |
4.5 V GND |
" " |
4.5 V GND |
GND GND |
GND GND |
GND 4.5 V |
" " |
GND 4.5 V |
VCC VCC |
50 50 |
" " |
||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125°C and VIC tests are omitted. |
||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||
7 TC=+25°C 21 31 |
55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 |
B " " " A " " " " " " B B A " " " " " B A " " " " " " |
B " " " " " A " " " " " B " " A B " " A " " " " " B B |
B B A " " B " " A " " " " " " B " " A " " " " B A " " |
4.5 V " " " " " " " " " " " " " " " " " " " " " " " " " " |
B B A " " B B A " " " " " " " B " " A " " " " B A " " |
B " " " " " A " " " " " B " " A B " " A " " " " " B B |
B " " " A " " " " " " B B A " " " " " B A " " " " " " |
B A A B " " " A A B A " " " B " " A " " " B A " " B A |
H L L H " " " L L H " " " L H " " L " " H " " L L H H |
H " " L L H " " " L " " " H L H " " " " L " " H H L L |
GND " " " " " " " " " " " " " " " " " " " " " " " " " " |
H " " L L H " " " L " " " H L H " " " " L " " H H L L |
H L L H " " " L L H " " " L H " " L " " H " " L L H H |
B A A B " " " A A B A " " " B " " A " " " B A " " B A |
All outputs " " " " " " " " " " " " " " " " " " " " " " " " " |
H or L as shown 41 " " " " " " " " " " " " " " " " " " " " " " " " " |
||||
8 21 31 |
Same tests, terminal conditions, and limits as for subgroup 7, except TC = +125°C and -55°C. |
||||||||||||||||||||
9 TC=+25°C |
fMAX 51 |
(Fig. 9) |
82 83 84 85 |
IN IN |
E E |
5.0 V " " " |
E E |
IN IN |
5.0 V 5.0 V |
OUT |
OUT |
GND " " " |
OUT |
OUT |
5.0 V 5.0 V |
Q1 Q1 Q2 Q2 |
35 " " " |
MHz " " " |
|||
tPLH1 |
3003 (Fig. 7) |
86 87 88 89 |
IN J |
" " " " |
IN J |
J IN |
OUT |
OUT |
" " " " |
OUT |
OUT |
J IN |
Clear 1 to Q1 Preset 1 to Q1 Clear 2 to Q2 Preset 2 to Q2 |
2 " " " |
20 " " " |
ns " " " |
|||||
tPHL1 |
90 91 92 93 |
IN J |
" " " " |
IN J |
J IN |
OUT |
OUT |
" " " " |
OUT |
OUT |
J IN |
Clear 1 to Q1 Preset 1 to Q1 Clear 2 to Q2 Preset 2 to Q2 |
" " " " |
32 " " " |
" " " " |
See footnotes at end of device type 03.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business