TABLE III. Group A inspection for device type 03 - Continued. 1/
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,B,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Case C |
3 |
2 |
1 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
5 |
4 |
Min |
Max |
|||||
Test no. |
Clock 1 |
D1 |
Clear 1 |
VCC |
Clear 2 |
D2 |
Clock 2 |
Preset 2 |
Q2 |
Q2 |
GND |
Q1 |
Q1 |
Preset 1 |
|||||||
9 TC=+25°C |
tPLH2 |
3003 (Fig. 8) (Fig. 9) (Fig. 8) (Fig. 9) |
94 95 96 97 |
IN IN |
IN(A) IN(A) |
B 5.0 V |
5.0 V " " " |
B 5.0 V |
IN(A) IN(A) |
IN IN |
5.0 V B |
OUT |
OUT |
GND " " " |
OUT |
OUT |
5.0 V B |
Clock 1 to Q1 Clock 1 to Q1 Clock 2 to Q2 Clock 2 to Q2 |
2 " " " |
17 " " " |
ns " " " |
tPHL2 |
3003 (Fig. 9) (Fig. 8) (Fig. 9) (Fig. 8) |
98 99 100 101 |
IN IN |
IN(B) IN(B) |
5.0 V B |
" " " " |
5.0 V B |
IN(B) IN(B) |
IN IN |
B 5.0 V |
OUT |
OUT |
" " " " |
OUT |
OUT |
B 5.0 V |
Clock 1 to Q1 Clock 1 to Q1 Clock 2 to Q2 Clock 2 to Q2 |
" " " " |
22 " " " |
" " " " |
|
10 TC=+125°C |
fMAX |
(Fig. 8) 5/ |
102 103 104 105 |
IN IN |
E E |
" " " " |
E E |
IN IN |
5.0 V 5.0 V |
OUT |
OUT |
" " " " |
OUT |
OUT |
5.0 V 5.0 V |
Q1 Q1 Q2 Q2 |
28 "' " " |
" " " " |
MHz " " " |
||
tPLH1 |
3003 (Fig. 7) |
106 107 108 109 |
IN J |
" " " " |
IN J |
J IN |
OUT |
OUT |
" " " " |
OUT |
OUT |
J IN |
Clear 1 to Q1 Preset 1 to Q1 Clear 2 to Q2 Preset 2 to Q2 |
2 " " " |
27 " " " |
ns " " " |
|||||
tPHL1 |
110 111 112 113 |
IN IN |
" " " " |
IN J |
J IN |
OUT |
OUT |
" " " " |
OUT |
OUT |
J IN |
Clear 1 to Q1 Preset 1 to Q1 Clear 2 to Q2 Preset 2 to Q2 |
" " " " |
38 " " " |
" " " " |
||||||
tPLH2 |
3003 (Fig. 8) (Fig. 9) (Fig. 8) (Fig. 9) |
114 115 116 117 |
IN IN |
IN(A) IN(A) |
B 5.0 V |
" " " " |
B 5.0 V |
IN(A) IN(A) |
IN IN |
5.0 V B |
OUT |
OUT |
" " " " |
OUT |
OUT |
5.0 V B |
Clock 1 to Q1 Clock 1 to Q1 Clock 2 to Q2 Clock 2 to Q2 |
" " " " |
22 " " " |
" " " " |
|
tPHL2 |
3003 (Fig. 9) (Fig. 8) (Fig. 9) (Fig. 8) |
118 119 120 121 |
IN IN |
IN(B) IN(B) |
5.0 V B |
" " " " |
5.0 V B |
IN(B) IN(B) |
IN IN |
B 5.0 V |
OUT |
OUT |
" " " " |
OUT |
OUT |
B 5.0 V |
Clock 1 to Q1 Clock 1 to Q1 Clock 2 to Q2 Clock 2 to Q2 |
" " " " |
28 " " " |
" " " " |
|
11 |
Same tests, terminal conditions, and limits as subgroup 10, except TC = -55°C |
A = Normal clock pulse.
B = Momentary GND, then 4.5 V. D = Momentary 4.5 V, then GND.
E = Input D connected to Q.
J = Input pulse tp � 100 ns, PRR = 1 MHz, VOL = 0 V, VOH = 4.5 V.
1/ Terminal conditions (pins not designated may be H � 2.0 V, or L ≤ 0.8 V, or open).
2/ Tests shall be performed in sequence.
3/ Input voltages shown are: A = 2.0 V minimum and B = 0.8 V maximum.
4/ Output voltages shall be either: a. H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker double comparator; or b. H � 1.5 V and L ≤ 1.5 V when using a high speed checker single comparator.
5/ The output frequency shall be one-half of the input frequency.