TABLE III. Group A inspection for device type 09 - Continued.
Terminal conditions 17/
Subgroup |
Symbol |
MIL- STD-883 method |
Case E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
Data B Input |
Output QB |
Output QA |
Count Down |
Count Up |
Output QC |
Output QD |
GND |
Data D Input |
Data C Input |
Load |
Carry Output |
Borrow Output |
Clear Input |
Data A Input |
vCC |
Min |
Max |
Unit |
||||
9 TC = 25°C |
tPLH11 " " " tPHL11 " " " |
Fig 9A " " " " " " " |
170 171 172 173 174 175 176 177 |
GND GND 2.4 v 2.4 v GND GND 2.4 v GND |
OUT OUT |
OUT OUT |
2.4 v " " " 16/ " " " |
15/ " " " 2.4 v " " " |
OUT OUT |
OUT OUT |
GND " " " " " " " |
GND " " " 2.4 v GND GND GND |
GND GND GND 2.4 v GND 2.4 v GND GND |
2.4 v " " " 16/ 16/ 16/ 16/ |
GND " " " " " " " |
GND 2.4 v 2.4 v 2.4 v GND GND GND 2.4 v |
5.0 v " " " " " " " |
QA QB QC QD QD QC QB QA |
3 " " " " " " " |
42 " " " 51 " " " |
ns " " " " " " " |
||
10 TC =125°C |
14/ FMAX 14/ FMAX tPHL7 tPLH8 tPHL8 tPHL9 tPLH9 tPHL10 tPLH10 tPLH11 " " " tPHL11 " " " |
Fig 9A Fig 9A Fig 9 Fig 9 Fig 9 Fig 9A " " " " " " " " " " " |
178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 |
2.4 v 2.4 v GND GND GND GND 2.4 v 2.4 v GND GND 2.4 v GND |
OUT OUT |
OUT " " " " OUT OUT |
2.4 v 4/ GND GND GND 2.4 v 2.4 v 10/ 11/ 2.4 v 2.4 v 2.4 v 2.4 v 16/ " " " |
4/ 2.4 v GND GND GND 8/ 9/ 2.4 v 2.4 v 15/ " " " 2.4 v " " " |
OUT OUT |
OUT OUT |
" " " " " " " " " " " " " " " " " |
2.4 v 2.4 v GND GND GND GND 2.4 v GND GND GND |
2.4 v 2.4 v GND GND GND GND GND 2.4 v GND 2.4 v GND GND |
2.4 v 2.4 v 5/ 6/ 7/ 8/ 9/ 2.4 v 2.4 v 2.4 v 2.4 v 2.4 v 2.4 v 16/ 16/ 16/ 16/ |
OUT OUT |
OUT OUT |
GND GND 5/ GND GND 8/ GND 9/ 10/ 11/ GND " " " " " " " |
2.4 v 6/ 7/ GND " " " GND 2.4 v 2.4 v 2.4 v GND GND GND 2.4 v |
" " " " " " " " " " " " " " " " " |
QA QA QA QA QA Carry Carry Borrow Borrow QA QB QC QD QD QC QB QA |
20 20 3 " " " " " " " " " " " " " " |
57 66 62 39 45 39 42 63 63 63 63 71 71 71 71 |
MHz MHz ns " " " " " " " " " " " " " " |
11 |
Same tests, terminal conditions, and limits as subgroup 10, except TC = -55°C. |
See footnotes on next page.