TABLE III. Group A inspection for device type 03.
Subgroup |
Symbol |
MIL- STD-883 method |
Case E,F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
Clear |
Clock |
DATA INPUTS |
Enable P |
GND |
Load |
Enable T |
Output QD |
Output QC |
Output QB |
Output QA |
Carry output |
VCC |
Min |
Max |
Unit |
|||||||
A |
B |
C |
D |
||||||||||||||||||||
1 TC = 25°C |
VOH " " " " |
3006 " " " " |
1 2 3 4 5 |
4.5 V " " " " |
1/ " " " " |
2.0 V 2.0 V |
2.0 V 0.8 V |
2.0 V 0.8 V |
2.0 V 2.0 V |
GND " " " " |
GND " " " " |
2.0 V |
-800µA |
-800µA |
-800µA |
-800µA |
-800µA |
4.5 V " " " " |
QD QC QB QA Carry |
2.4 " " " " |
V " " " " |
||
VOL " " " " |
3007 " " " " |
6 7 8 9 10 |
" " " " " |
" " " " |
0.8 V |
0.8 V |
0.8 V |
0.8 V |
0.8 V " " " " |
" " " " " |
" " " " " |
0.8 V " " " " |
16 mA |
16 mA |
16 mA |
16 mA |
16 mA |
" " " " " |
QD QC QB QA Carry |
0.4 " " " " |
" " " " " |
||
VIC " " " " " " " " |
11 12 13 14 15 16 17 18 19 |
-12mA |
-12mA |
-12mA |
-12mA |
-12mA |
-12mA |
-12mA |
" " " " " " " " " |
-12mA |
-12mA |
" " " " " " " " " |
Input A Input B Input C Input D Enable P Load Enable T Clear Clock |
-1.5 " " " " " " " " |
" " " " " " " " " |
||||||||
IIH9 IIH9 IIH10 IIH10 |
3010 " " " |
20 21 22 23 |
1/ 1/ |
2.4 V 5.5 V |
GND GND |
GND GND |
GND GND |
GND GND |
GND GND |
" " " " |
GND GND |
2.4 V 5.5 V |
5.5 V " " " |
Clock Enable T Clock Enable T |
80 80 200 200 |
µA " " " |
|||||||
IIH11 " " " " " " |
" " " " " " " |
24 25 26 27 28 29 30 |
2.4 V |
2.4 V |
2.4 V |
2.4 V |
2.4 V |
2.4 V |
" " " " " " " |
5.5 V " " " 2.4 V |
GND |
" " " " " " " |
Clear Input A Input B Input C Input D Enable P Load |
40 " " " " " " |
" " " " " " " |
||||||||
IIH12 " " " " " " |
" " " " " " " |
31 32 33 34 35 36 37 |
5.5 V |
5.5 V |
5.5 V |
5.5 V |
5.5 V |
5.5 V |
" " " " " " " |
5.5 V " " " 5.5 V |
GND |
" " " " " " " |
Clear Input A Input B Input C Input D Enable P Load |
100 " " " " " " |
" " " " " " " |
||||||||
IIL5 |
3009 |
38 |
0.4 V |
" |
" |
Clock |
-1.0 |
-2.3 |
mA |
See footnotes at end of device type 03.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business