TABLE III. Group A inspection for device type 05 - Continued.
Terminal conditions 2/
Subgroup |
Symbol |
MIL- STD-883 method |
Case E,F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
Clear |
Clock |
DATA INPUTS |
Enable P |
GND |
Load |
Enable T |
Output QD |
Output QC |
Output QB |
Output QA |
Carry output |
VCC |
Min |
Max |
Unit |
|||||||
A |
B |
C |
D |
||||||||||||||||||||
7 TC = 25°C |
Func- tional tests 4/ " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
3014 " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 |
A 5/ " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
A 5/ B A A B A A B A A B A A B A A B A A B A A B A A B A A B A A B A |
B 5/ " " " " " " " " " " " A A A B B B A A A B " " " " " A " " " " " |
B 5/ A A B " " " " " A " " " " " B " " " " " A A A B " " " " " A A A |
B 5/ " " " " " " " " A A A B B B A " " " " " " " " B " " " " " A A A |
B 5/ B B A A A B B B A A A B " " " " " " " " " " " A " " " " " " " " |
A 5/ " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
GND " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
B 5/ " " " " " " " " " " " " " " " " " " " " " " " " " " " " " A A A |
B 5/ " " " " " A " " " " " " " " " " " " " " " " " " " " " " " " " " |
L " " " " H H H L L L H H H L " " " " " " " " " " " H " " " " " L |
L " " " " " " " " " " H H H L L L H " " " " " " " " L " " " " " " |
L " H H H L " " " " " H " " " " " L " " " " " H H H L " " " " " " |
L " " " " " " " " " " " " " H H H L L L H H H L " " " " " H H H L |
L " " " " " " " " " " " " " " " " " " " " " " " " " " " " H H H L |
4.5 V " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
See 3/ |
|||
8 |
Repeat subgroup 7 at TC = 125°C and TC = -55°C. |
||||||||||||||||||||||
9 TC = 25°C |
6/ FMAX tPLH3 tPHL3 tPHL4 tPHL4 tPHL4 tPHL4 |
Fig 7&7C Fig 7&7B " " " " " |
152 153 154 155 156 157 158 |
4.5 V " " " " " " |
IN " " " " " " |
GND 4.5 V " " " " |
GND " " 4.5 V 4.5 V GND |
GND " " " 4.5 V GND |
4.5 V 4.5 V GND " " 4.5 V |
4.5 V " " " " " " |
GND " " " " " " |
4.5 V IN " " " " " |
4.5 V " " " " " " |
OUT |
OUT |
OUT |
OUT OUT |
OUT OUT |
5.0 V " " " " " " |
QA Carry Carry QA QB QC QD |
20 3 " " " " " |
45 45 30 " " " |
MHz ns " " " " " |
See footnotes at end of device type 05.