TABLE III. Group A inspection for device type 07 - Continued.
Terminal conditions 12/
1/ Momentarily apply 2.0 V, then ground prior to taking measurements to set the device in desired state. Maintain ground for measurement.
2/ Apply 4.5 V pulse then ground prior to taking measurements to set the device in the desired state. Maintain ground for measurement.
3/ Apply one pulse after reset (R0) pulses.
4/ Apply two pulses after reset (R0) pulses.
5/ Only a summary of attributes data is required.
6/ A > 2.0 V, B < 0.8 V. Input voltages shown are the maximum for VIL and the minimum for VIH.
7/ Output voltages shall be either:
(a) H = 2.4 volts minimum and L = 0.4 volt maximum when using a high speed checker double comparator, or
(b) H > 1.5 volts and L < 1.5 volts when using a high speed checker single comparator.
8/ FMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
9/ Connect terminals together during test.
10/ See test figure 8 for terminal load.
11/ Omit specified loads for this test.
12/ Terminal conditions (pins not designated may be H > 2.0 V, or L < 0.8 V, open).
13/ The limits shown shall be as follows:
Test |
Min/Max limits (ma) for circuit: |
||
A |
B |
C |
|
IIL1 |
-0.4/-1.3 |
-0.4/-1.3 |
-0.7/-1.6 |
IIL2 |
-1.4/-3.2 |
-0.7/-3.2 |
-0.7/-3.2 |
IIL3 |
-1.4/-4.8 |
-0.7/-4.8 |
-1.4/-6.4 |