MIL-M-38510/13G
NOTES:
1. The pulse generators have the following characteristics: Zout = 50 Ω; for the data pulse generator, PRR ≤ 500 kHz, duty cycle = 50%; for the load pulse generator, PRR = 1 MHz, duty cycle = 50%.
2. CL includes probe and jig capacitance.
3. All diodes are 1N3064, or equivalent.
FIGURE 9. Switching time test circuits and waveforms for device types 08 and 09.
41
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.