TABLE III. Group A inspection for device type 08 -Continued.
Subgroup |
Symbol |
Test no. |
Adapter pin number 1/ |
Relays energized |
Measured pin no. |
Limits |
Unit |
||||||||||||||
1 IN1 |
2 S1 |
3 S3 |
4 S2 |
5 S4 |
6 +VCC |
7 -VCC |
8 VR |
9 VL |
10 D1 |
11 D3 |
12 D2 |
13 D4 |
14 IN2 |
Min |
Max |
||||||
4 TA =+25°C |
VCTE " " " |
109 110 111 112 |
IN 3/ IN 3/ |
GND |
GND |
GND |
GND |
15 V " " " |
-15 V " " " |
GND " " " |
5.0 V " " " |
IN 3/ IN 3/ |
K2 K4 K5 K3 |
10 11 12 13 |
20 20 20 20 |
mVp-p " " " |
|||||
7 TA =+25°C |
VCT 7/ |
113 114 115 116 |
2.0 V 0.8 V |
IN 4/ |
IN 4/ |
IN 4/ |
IN 4/ |
" " " " |
" " " " |
" " " " |
" " " " |
2.0 V 0.8 V |
K1 K1 K1 K1 |
11 10 13 12 |
60 |
1.0 " " " |
" " " " dB |
||||
dBCT = -20 log (VOUT/VIN) |
|||||||||||||||||||||
VISO |
117 118 119 120 |
0.8 V 2.0 V |
IN 4/ |
IN 4/ |
IN 4/ |
IN 4/ |
15 V " " " |
-15 V " " " |
GND " " " |
5.0 V " " " " |
0.8 V 2.0 V |
K1 K1 K1 K1 |
10 11 12 13 |
0 0 0 0 50 |
3.16 3.16 3.16 3.16 |
mVp-p " " " dB |
|||||
dBISO = -20 log (VOUT/VIN) |
|||||||||||||||||||||
9 TA =+25°C |
tON |
121 122 123 124 |
IN IN |
IN |
IN |
IN |
IN |
15 V " " " |
-15 V " " " |
GND " " " |
5.0 V " " " |
OUT |
OUT |
OUT |
OUT |
IN IN |
K6 K8 K9 K7 |
2 to 10 3 to 11 4 to 12 5 to 13 |
250 " " " |
ns " " " |
|
tOFF |
125 126 127 128 |
IN IN |
IN |
IN |
IN |
IN |
" " " " |
" " " " |
" " " " |
" " " " |
OUT |
OUT |
OUT |
OUT |
K6 K8 K9 K7 |
2 to 10 3 to 11 4 to 12 5 to 13 |
130 " " " |
" " " " |
|||
10 TA =+125°C |
tON |
129 130 131 132 |
IN IN |
IN |
IN |
IN |
IN |
" " " " |
" " " " |
" " " " |
" " " " |
OUT |
OUT |
OUT |
OUT |
IN IN |
K6 K8 K9 K7 |
2 to 10 3 to 11 4 to 12 5 to 13 |
350 " " " |
" " " " |
See footnotes at end of table.