TABLE III. Group A inspection for device type 07 -Continued.
Subgroup |
Symbol |
Test no. |
Adapter pin number 1/ |
Relays energized |
Measured pin no. |
Limits |
Unit |
||||||||||||||
1 IN1 |
2 S1 |
3 S3 |
4 S2 |
5 S4 |
6 +vCC |
7 -vCC |
8 vR |
9 vL |
10 D1 |
11 D3 |
12 D2 |
13 D4 |
14 IN2 |
Min |
Max |
||||||
2 TA = 125°C |
ID(ON)+ IS(ON) " " |
57 58 59 60 |
2.0 v 0.8 v |
-7.5 v |
-7.5 v |
-7.5 v |
-7.5 v |
15 v " " " |
-15 v " " " |
GND " " " |
5.0 v " " " |
-7.5 v |
-7.5 v |
-7.5 v |
-7.5 v |
2.0 v 0.8 v |
K10 K11 K12 K13 |
2 3 4 5 |
-200 " " " |
200 " " " |
nA " " " |
IIL IIL |
61 62 |
GND |
" " |
" " |
" " |
" " |
GND |
None " |
1 14 |
-250 -250 |
-0.1 -0.1 |
∝A ∝A |
|||||||||
IIH IIH |
63 64 |
5.0 v |
" " |
" " |
" " |
" " |
5.0 v |
" " |
1 14 |
-2 -2 |
20 20 |
∝A ∝A |
|||||||||
+ICC +ICC |
65 66 |
GND 5.0 v |
" " |
" " |
" " |
" " |
GND 5.0 v |
" " |
6 6 |
1.5 1.5 |
mA " |
||||||||||
-ICC -ICC |
67 68 |
GND 5.0 v |
" " |
" " |
" " |
" " |
GND 5.0 v |
" " |
7 7 |
-5 -5 |
" " |
||||||||||
IL IL |
69 70 |
GND 5.0 v |
" " |
" " |
" " |
" " |
GND 5.0 v |
" " |
9 9 |
4.5 4.5 |
" " |
||||||||||
IR IR |
71 72 |
GND 5.0 v |
" " |
" " |
" " |
" " |
GND 5.0 v |
" " |
8 8 |
-2.2 -2.2 |
" " |
||||||||||
3 TA = -55°C |
RDS " " " |
73 74 75 76 |
2.0 v 0.8 v |
-10 mA |
-10 mA |
-10 mA |
-10 mA |
" " " " |
" " " " |
" " " " |
" " " " |
-7.5 v |
-7.5 v |
-7.5 v |
-7.5 v |
2.0 v 0.8 v |
" " " " |
2 3 4 5 |
-7.8 " " " |
v 2/ v 2/ v 2/ v 2/ |
|
IS(OFF) " " " " " " " |
77 78 79 80 81 82 83 84 |
0.8 v 2.0 v 0.8 v 2.0 v |
10 v 7.5 v |
10 v 7.5 v |
10 v 7.5 v |
10 v 7.5 v |
10 v " " " 15 v " " " |
-20 v " " " -15 v " " " |
" " " " " " " " |
" " " " " " " " |
-10 v -7.5 v |
-10 v -7.5 v |
-10 v -7.5 v |
-10 v -7.5 v |
0.8 v 2.0 v 0.8 v 2.0 v |
" " " " " " " " |
2 3 4 5 2 3 4 5 |
-100 " " " " " " " |
100 " " " " " " " |
nA " " " " " " " |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business