TABLE III. Group A inspection for device type 09 - Continued.
Subgroup |
Symbol |
MIL- STD- 883 method |
Test no. |
Pin number and signal designation |
Measured terminal |
Limits |
Unit |
||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
Min |
Max |
||||||
IN1 |
IN2 |
IN3 |
IN4 |
IN5 |
IN6 |
IN7 |
IN8 |
GND |
COM |
OUT8 |
OUT7 |
OUT6 |
OUT5 |
OUT4 |
OUT3 |
OUT2 |
OUT1 |
||||||||
3 TA = -55°C |
vIN(on) |
281 282 283 284 285 286 287 288 |
6.0 v |
6.0 v |
6.0 v |
6.0 v |
6.0 v |
6.0 v |
6.0 v |
6.0 v |
0 v " " " " " " " |
125 mA |
125 mA |
125 mA |
125 mA |
125 mA |
125 mA |
125 mA |
125 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 |
2.0 " " " " " " " |
v " " " " " " " |
|||
vIN(on) |
289 290 291 292 293 294 295 296 |
8.0 v |
8.0 v |
8.0 v |
8.0 v |
8.0 v |
8.0 v |
8.0 v |
8.0 v |
0 v " " " " " " " |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 |
2.0 " " " " " " " |
v " " " " " " " |
||||
vIN(on) |
297 298 299 300 301 302 303 304 |
10.0 v |
10.0 v |
10.0 v |
10.0 v |
10.0 v |
10.0 v |
10.0 v |
10.0 v |
0 v " " " " " " " |
275 mA |
275 mA |
275 mA |
275 mA |
275 mA |
275 mA |
275 mA |
275 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 |
2.0 " " " " " " " |
v " " " " " " " |
||||
vIN(on) |
305 306 307 308 309 310 311 312 |
12.0 v |
12.0 v |
12.0 v |
12.0 v |
12.0 v |
12.0 v |
12.0 v |
12.0 v |
0 v " " " " " " " |
350 mA |
350 mA |
350 mA |
350 mA |
350 mA |
350 mA |
350 mA |
350 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 |
2.0 " " " " " " " |
v " " " " " " " |
||||
IR |
313 314 315 316 317 318 319 320 |
0 v " " " " " " " |
50 v " " " " " " " |
0 v |
0 v |
0 v |
0 v |
0 v |
0 v |
0 v |
0 v |
COM COM COM COM COM COM COM COM |
10.0 " " " " " " " |
µA " " " " " " " |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business