TABLE III. Group A inspection for device type 04 - Continued.
Subgroup |
Symbol |
MIL- STD- 883 method |
Test no. |
Pin number and signal designation |
Measured terminal |
Limits |
Unit |
||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Min |
Max |
||||||
IN1 |
IN2 |
IN3 |
IN4 |
IN5 |
IN6 |
IN7 |
GND |
COM |
OUT7 |
OUT6 |
OUT5 |
OUT4 |
OUT3 |
OUT2 |
OUT1 |
||||||||
3 TA = -55°C |
VCE(sat) |
3007 |
211 212 213 214 215 216 217 |
550 µA |
550 µA |
550 µA |
550 µA |
550 µA |
550 µA |
550 µA |
0 V " " " " " " |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 |
1.5 " " " " " " |
V " " " " " " |
||
VCE(sat) |
3007 |
218 219 220 221 222 223 224 |
350 µA |
350 µA |
350 µA |
350 µA |
350 µA |
350 µA |
350 µA |
" " " " " " " |
100 mA |
100 mA |
100 mA |
100 mA |
100 mA |
100 mA |
100 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 |
1.3 " " " " " " |
V " " " " " " |
|||
IIN(on) |
225 226 227 228 229 230 231 |
5.0 V |
5.0 V |
5.0 V |
5.0 V |
5.0 V |
5.0 V |
5.0 V |
" " " " " " " |
IN1 IN2 IN3 IN4 IN5 IN6 IN7 |
250 " " " " " " |
500 " " " " " " |
µA " " " " " " |
||||||||||
IIN(on) |
232 233 234 235 236 237 238 |
12.0 V |
12.0 V |
12.0 V |
12.0 V |
12.0 V |
12.0 V |
12.0 V |
" " " " " " " |
IN1 IN2 IN3 IN4 IN5 IN6 IN7 |
750 " " " " " " |
1450 " " " " " " |
µA " " " " " " |
||||||||||
IIN(off) |
239 240 241 242 243 244 245 |
25 µA |
25 µA |
25 µA |
25 µA |
25 µA |
25 µA |
25 µA |
" " " " " " " |
50 V |
50 V |
50 V |
50 V |
50 V |
50V |
50 V |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 |
500 " " " " " " |
µA " " " " " " |
||||
VIN(on) |
246 247 248 249 250 251 252 |
6.0 V |
6.0 V |
6.0 V |
6.0 V |
6.0 V |
6.0 V |
6.0 V |
0 V " " " " " " |
125 mA |
125 mA |
125 mA |
125 mA |
125 mA |
125 mA |
125 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 |
2.0 " " " " " " |
V " " " " " " |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business