TABLE III. Group A inspection for device type 08 - Continued.
Subgroup |
Symbol |
MIL- STD- 883 method |
Test no. |
Pin number and signal designation |
Measured terminal |
Limits |
Unit |
||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
Min |
Max |
||||||
IN1 |
IN2 |
IN3 |
IN4 |
IN5 |
IN6 |
IN7 |
IN8 |
GND |
COM |
OUT8 |
OUT7 |
OUT6 |
OUT5 |
OUT4 |
OUT3 |
OUT2 |
OUT1 |
||||||||
3 TA = -55°C |
IIN(off) |
233 234 235 236 237 238 239 240 |
25 µA |
25 µA |
25 µA |
25 µA |
25 µA |
25 µA |
25 µA |
25 µA |
0 V " " " " " " " |
50 V |
50 V |
50 V |
50 V |
50 V |
50 V |
50V |
50 V |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 |
500 " " " " " " " |
µA " " " " " " " |
|||
VIN(on) |
241 242 243 244 245 246 247 248 |
2.6 V |
2.6 V |
2.6 V |
2.6 V |
2.6 V |
2.6 V |
2.6 V |
2.6 V |
0 V " " " " " " " |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
200 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 |
2.0 " " " " " " " |
V " " " " " " " |
||||
VIN(on) |
249 250 251 252 253 254 255 256 |
2.8 V |
2.8 V |
2.8 V |
2.8 V |
2.8 V |
2.8 V |
2.8 V |
2.8 V |
0 V " " " " " " " |
250 mA |
250 mA |
250 mA |
250 mA |
250 mA |
250 mA |
250 mA |
250 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 |
2.0 " " " " " " " |
V " " " " " " " |
||||
VIN(on) |
257 258 259 260 261 262 263 264 |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
3.0 V |
0 V " " " " " " " |
300 mA |
300 mA |
300 mA |
300 mA |
300 mA |
300 mA |
300 mA |
300 mA |
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 |
2.0 " " " " " " " |
V " " " " " " " |
||||
IR |
265 266 267 268 269 270 271 272 |
0 V " " " " " " " |
50 V " " " " " " |
0 V |
0 V |
0 V |
0 V |
0 V |
0 V |
0 V |
0 V |
COM COM COM COM COM COM COM COM |
10.0 " " " " " " " |
µA " " " " " " " |