MIL-M-38510/140A
Test setup timing specifications
STAND ALONE MODE
Symbol |
Parameter |
Min |
Unit |
tHRL |
Low R/ C pulse width |
350 |
ns |
tHRH |
High R/ C pulse width |
250 |
ns |
NOTE: For stand-alone operation, CE is tied to logic "1", 12/ 8 is wired to +5 V, and CS and A0 are tied to logic "0".
Test parameter tRR is measured with the following load circuit and the access time is defined as the time required for an output to reach 0.4 V and 2.4 V for VOL and VOH, respectively.
Test parameter tHDR is measured with the following load circuit and the float delay time is defined as the time required for an output to reach 0.8 V and 2.0 V from a logic "0" and from "1", respectively.
FIGURE 9. Timing diagrams (stand alone operation) - Continued.