MIL-M-38510/140A
ANALOG INPUT VOLTAGE (VOLTS) |
DIGITAL OUTPUT |
|||
0 to +10 V |
0 to +20 V |
±5 V |
±10 V |
MSB LSB |
+10.0000 |
+20.0000 |
+5.0000 |
+10.0000 |
1111 1111 1111 |
+9.9963 |
+19.9927 |
+4.9963 |
+9.9927 |
1111 1111 111> |
+5.0012 |
+10.0024 |
+0.0012 |
+0.0024 |
1000 0000 000> |
+4.9988 |
+9.9976 |
-0.0012 |
-0.0024 |
>>>> >>>> >>>> |
+4.9963 |
+9.9927 |
-0.0037 |
-0.0073 |
0111 1111 111> |
+0.0012 |
+0.0024 |
-4.9988 |
-9.9976 |
0000 0000 000> |
+0.0000 |
0.000 |
-5.000 |
-10.0000 |
0000 0000 0000 |
Control Inputs |
Operation |
||||
CE |
CS |
R / C |
12 / 8 |
A0 |
|
0 |
x |
x |
x |
x |
No operation |
x |
1 |
x |
x |
x |
No operation |
1 |
0 |
1-0 |
x |
0 |
Initiates 12-bit conversion |
1 |
0 |
1-0 |
x |
1 |
Initiates 8-bit conversion |
0-1 |
0 |
0 |
x |
0 |
Initiates 12-bit conversion |
0-1 |
0 |
0 |
x |
1 |
Initiates 8-bit conversion |
1 |
1-0 |
0 |
x |
0 |
Initiates 12-bit conversion |
1 |
1-0 |
0 |
x |
1 |
Initiates 8-bit conversion |
1 |
0 |
0-1 |
VLOG |
x |
Enable 12-bit parallel output |
1 |
0 |
0-1 |
0.0 V |
0 |
Enables 8 MSB's |
1 |
0 |
0-1 |
0.0 V |
1 |
Enables 4 LSB's and 4 trailing zero's |
Figure 2. Functional block diagram and operational information - Continued.