MIL-M-38510/140A
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions -55°C ≤ TA ≤ +125°C unless otherwise specified see 3.6 and figures 4 and 8 |
Device type |
Limits 1/ |
Unit |
|
Min |
Max |
|||||
Integral linearity error |
LE |
(Abbreviated test), -55°C ≤ TA ≤ +125°C, figures 6 and 8 |
All |
-1.0 |
1.0 |
LSB |
(Abbreviated test), TA = +25°C, figures 6 and 8 |
-0.5 |
0.5 |
||||
Integral linearity error |
LE |
(All codes test), -55°C ≤ TA ≤ +125°C, figures 6 and 8 |
All |
-1.0 |
1.0 |
LSB |
(All codes test), TA = +25°C, figures 6 and 8 |
-0.5 |
0.5 |
||||
Differential linearity error |
DLE |
(Abbreviated test), -55°C ≤ TA ≤ +125°C, figures 6 and 8 |
All |
-0.9 |
2.0 |
LSB |
(Abbreviated test), TA = +25°C, figures 6 and 8 |
-0.9 |
1.0 |
||||
STS delay from CE |
tDSC |
Low to high transition, referenced to low to high CE transition, output code = 0000 0000 0000 2/ TA = +25°C, figures 7 and 8 |
All |
350 |
ns |
|
Data access time from CE |
tDD |
Output data valid, referenced to low to high CE transition, output code = 0000 0000 0000 and 1111 1111 1111 2/ TA = +25°C, figures 7 and 8 |
01,02, 03,04 |
200 |
ns |
|
05,06 |
250 |
|||||
Data valid after CE low |
tHD |
Output data valid, referenced to high to low CE transition, output code = 0000 0000 0000 and 1111 1111 1111 2/ TA = +25°C, figures 7 and 8 |
All |
25 |
ns |
|
STS delay after data valid |
tHS |
High to low transition referenced to data valid, output code = 0000 0000 0000 and 1111 1111 1111 2/ TA = +25°C, figures 7 and 8 |
01,02, 03,04 |
300 |
1000 |
ns |
05,06 |
100 |
600 |
||||
Output float delay |
tHL |
Output delay to Hi-Z, referenced to high to low CE transition, output code = 0000 0000 0000 and 1111 1111 1111 2/ TA = +25°C, figures 7 and 8 |
01,02 |
100 |
ns |
|
03,04, 05,06 |
150 |
See footnotes at end of table.