MIL-M-38510/140A
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions -55°C ≤ TA ≤ +125°C unless otherwise specified see 3.6 and figures 4 and 8 |
Device type |
Limits 1/ |
Unit |
|
Min |
Max |
|||||
STS delay from R/ C |
tDS |
Low to high transition, referenced to high to low R/ C transition, output code = 0000 0000 0000 2/ TA = +25°C, figures 7 and 8 |
All |
600 |
ns |
|
Data access time from R/ C |
tDDR |
Output data valid, referenced to low to high R/ C transition, output code = 0000 0000 0000 and 1111 1111 1111 2/ TA = +25°C, figures 7 and 8 |
All |
250 |
ns |
|
Data valid after R/ C low |
tHDR |
Output data valid, referenced to high to low R/ C transition, output code = 0000 0000 0000 and 1111 1111 1111 2/ TA = +25°C, figures 7 and 8 |
All |
25 |
ns |
|
Output short circuit current |
IOSC |
VLOG = 5.5 V, output code = 1111 1111 1111 and 2/ STS output = logic "1", TA = 25°C, measured separately to ground |
All |
-40 |
mA |
|
VLOG = 5.5 V, output code = 0000 0000 0000 and 2/ STS output = logic "0", TA = 25°C, measured separately to VLOG |
75 |
|||||
Input resistance |
Ri |
VIN(analog) = 1/2 V, TA = 25°C |
All |
3 |
7 |
kn |
Transition uncertainty |
NT |
Output transition = φφφφ φφφφ φφφφ and 1111 1111 1111 6/ Range = 16% to 84%, TA = 25°C (figures 6 and 8) |
All |
-0.5 |
0.5 |
LSB |
1/ See paragraph 6.5 for symbols and definitions.
2/ An output code of 0000 0000 0000 is guaranteed by an input voltage VIN = -7.0 mV and an output code of 1111 1111 1111 is guaranteed by an input voltage VIN = 10.08 V.
3/ PD = (VCC *ICC +VEE *IEE +VLOGIC *ILOGIC). Power dissipation shall be calculated using the two output code conditions 0000 0000 0000 and 1111 1111 1111.
4/ The reference voltage external load current shall be constant dc and shall not exceed 1.5 mA.
5/ Changing A0 during the ready cycle, may result in damage to the device output buffers. Therefore, it is recommended that CE is low or CS is high before A0 is changed.
6/ φ represent the transition point between two adjacent code words (for example: 0000 0000 000φ)
represents the transition between code words 0000 0000 0000 and 0000 0000 0001, φφφφ φφφφ φφφφ
represents the transition between code words 0111 1111 1111 and 1000 0000 0000 and
1111 1111 111φ represents the transition between code words 1111 1111 1110 and 1111 1111 1111.