MlL-M-38510/110C
TABLE lV. Group C and Group B life test end point electrical parameters. (TA = +25°C, ±VCC = ±20 V for device types 01 - 04 and
+VCC = 30 V for device types 05 and 06).
Table lll test no. |
Test |
01, 02 |
03 |
Unit |
||||||
Limit |
Delta |
Limit |
Delta |
|||||||
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
|||
3 |
VlO |
-5 |
+5 |
-1 |
+1 |
-3.0 |
+3.0 |
-0.5 |
+0.5 |
mV |
11 |
+llB |
+0.1 |
+100 |
-15 |
+15 |
-200 |
-1 |
-20 |
20 |
nA |
15 |
-llB |
+0.1 |
+100 |
-15 |
+15 |
-200 |
-1 |
-20 |
20 |
nA |
Table lll test no. |
Test |
04 |
05 |
Unit |
||||||
Limit |
Delta |
Limit |
Delta |
|||||||
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
|||
3 |
VlO |
-5 |
+5 |
-1 |
+1 |
-5 |
+5 |
-1 |
+1 |
mV |
11 |
+llB |
-250 |
-1 |
-25 |
+25 |
-150 |
-1 |
-15 |
+15 |
nA |
15 |
-llB |
-250 |
-1 |
-25 |
+25 |
-150 |
-1 |
-15 |
+15 |
nA |
Table lll test no. |
Test |
06 |
Unit |
|||
Limit |
Delta |
|||||
Min |
Max |
Min |
Max |
|||
3 |
VlO |
-2 |
+2 |
-0.5 |
+0.5 |
mV |
11 |
+llB |
-50 |
-1 |
-10 |
+10 |
nA |
15 |
-llB |
-50 |
-1 |
-10 |
+10 |
nA |
1/ For device types 05 and 06, the table lll test numbers are as follows: VlO use test number 1,
+llB use the test number 9, -llB use test number 13.
36
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business