MIL-M-385101110C
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions -55°C = TA = +125°C see figure 2 unless otherwise specified |
Group A subgroups |
Device type |
Limits |
Unit |
|
Min |
Max |
||||||
Channel separation |
CS |
TA = +25°C, see figure 7 |
7 |
01,02, 03,04, 05,06, 07,08 |
80 |
dB |
11 Device types 01 to 04 shall be tested at VCM = 0 V, +15 V, and -15 V with ±VCC = ±20 V; and at VCM = 0 V with
±VCC = ±5 V. Device types 05 and 06 should be tested at VCM = -13 V with VCC = 2 V and -VCC = -28 V; VCM = +15 V with +VCC = 30 V and -VCC = 0 V; VCM = +1.4 V with VCC = 5 V and -VCC = 0 V;
VCM = -1.1 V at ±VCC = 2.5 V.
21 CMR is determined by measuring input offset voltage as follows:
Offset voltage condition |
Device types |
Units |
|||||
01 - 04 |
05 and 06 |
||||||
+VCC |
-VCC |
VO |
+VCC |
-VCC |
VO |
||
1 |
35 |
-5 |
15 |
30 |
0 |
15 |
V |
2 |
5 |
-35 |
-15 |
2 |
-28 |
-13 |
V |
31 Continuous limits will be considerably lower and apply for -55°C ≤ TA ≤ 25°C.
41 ISO(+) and ISO(-) limits for device type 01 only at TA = -55°C are -75 mA and 75 mA respectively.
51 ICC limits are the total for all four amplifiers at no load, connected as grounded followers.
61 AVS(+) for device types 05 and 06 only.
71 Device types 05 and 06 transient response is specified with the input pulse referenced to 5 V. For application purposes the device may be operated with the input referenced to ground, however, saturation effects will cause the response time to increase by approximately 50 percent.