Subgroup |
Symbol |
MIL-STD -883 method |
Test no. |
Adapter pin numbers |
Energized relays 2I |
Measured pins |
Equations 3I |
Device types |
Unit |
|||||||
05, 05 |
||||||||||||||||
Limits |
||||||||||||||||
1 |
2 |
3 |
4 |
5 |
No. |
Value |
Unit |
Min |
Max |
|||||||
7 TA =+25°C |
CS |
104 |
30 V |
GND |
16 V |
-1.4 V |
See fig. 3 " " " " " " " " " " " " " " " |
5 |
E87 |
V " " " " " " " " " " " " " " " |
CS = 20 log 4 11.5 x 10 I E87 - E881 |
80 |
dB " " " " " " " " " " " " " " " |
|||
30 V |
GND |
1 V |
-1.4 V |
E88 |
80 |
|||||||||||
105 |
30 V |
GND |
16 V |
-1.4 V |
E89 |
CS = 20 log 4 11.5 x 10 I E89 - E901 |
80 |
|||||||||
30 V |
GND |
1 V |
-1.4 V |
E90 |
80 |
|||||||||||
106 |
30 V |
GND |
16 V |
-1.4 V |
E91 |
CS = 20 log 4 11.5 x 10 I E91 - E921 |
80 |
|||||||||
30 V |
GND |
1 V |
-1.4 V |
E92 |
80 |
|||||||||||
107 |
30 V |
GND |
16 V |
-1.4 V |
E93 |
CS = 20 log 4 11.5 x 10 I E93 - E941 |
80 |
|||||||||
30 V |
GND |
1 V |
-1.4 V |
E94 |
80 |
|||||||||||
108 |
30 V |
GND |
16 V |
-1.4 V |
E95 |
CS = 20 log 4 11.5 x 10 I E95 - E961 |
80 |
|||||||||
30 V |
GND |
1 V |
-1.4 V |
E96 |
80 |
|||||||||||
109 |
30 V |
GND |
16 V |
-1.4 V |
E97 |
CS = 20 log 4 11.5 x 10 I E97 - E981 |
80 |
|||||||||
30 V |
GND |
1 V |
-1.4 V |
E98 |
80 |
|||||||||||
110 |
30 V |
GND |
16 V |
-1.4 V |
E99 |
CS = 20 log 4 11.5 x 10 I E99 - E1001 |
80 |
|||||||||
30 V |
GND |
1 V |
-1.4 V |
E100 |
80 |
|||||||||||
111 |
30 V |
GND |
16 V |
-1.4 V |
E101 |
CS = 20 log 4 11.5 x 10 I E101 - E1021 |
80 |
|||||||||
30 V |
GND |
1 V |
-1.4 V |
E102 |
80 |
|||||||||||
TR(tr) TR(os) |
112 |
30 V |
GND |
IN |
OUT |
See fig. 4 " " " |
t |
∝s |
(Waveform 1) TR(tr) = t (Waveform 1) TR(OS) = 100 (VOIVO) |
1.0 |
∝s |
|||||
113 |
30 V |
GND |
IN |
OUT |
VO;VO |
V |
60 |
% |
||||||||
SR(+) |
4002 " |
114 |
30 V |
GND |
IN |
OUT |
VO; t |
V; ∝s |
(Waveform 2) SR(+) = VOIt (Waveform 3) SR(-) = VOIt |
0.1 |
VI∝s |
|||||
SR(-) |
115 |
30 V |
GND |
IN |
OUT |
VO; t |
V; ∝s |
0.1 |
VI∝s |
|||||||
8 |
116 to 123 |
Same tests, terminal conditions and limits as subgroup 7, tests 112 through 115 except TA = 125°C and TA = -55°C. |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business