MIL-M-38510/110C
Test requirements.
CS test number* |
Channels tested |
Relays energized |
||
All device types |
Additional for device type 02 |
|||
Driven |
Monitored |
Driven |
||
103 (100) |
A to B |
3,4,9 |
10,11,12,15,17 |
5,6,7 |
104 (101) |
A to C |
" |
19,20,21,24,26 |
" |
105 (102) |
A to D |
" |
28,29,30,33.35 |
" |
106 (103) |
B to A |
12,13,18 |
1,2,3,6,8 |
14,15,16 |
107 (104) |
B to C |
" |
19,20,21,24,26 |
" |
108 (105) |
B to D |
" |
28,29,30,33,35 |
" |
109 (106) |
C to A |
21,22,27 |
1,2,3,6,8 |
23,24,25 |
110 (107) |
C to B |
" |
10,11,12,15,17 |
" |
111 (108) |
C to D |
" |
28,29,30,33,35 |
" |
112 (109) |
D to A |
30,31,36 |
1,2,3,6,8 |
32,33,34 |
113 (110) |
D to B |
" |
10,11,12,15,17 |
" |
114 (111) |
D to C |
" |
19,20,21,24,26 |
" |
* Numbers in parenthesis apply to device types 05 and 06.
1/ All resistors are ±0.1 % tolerance and all capacitors are ±10%.
2/ Precautions shall be taken to prevent damage to the device under test during insertion into socket and change of state relays (i.e. disable voltage supplies, current limit ±VCC, etc.).
3/ All relays are shown in the normal de-energized state. The above table shall be used to determine which relays to energize for each test.
4/ R1 and R2 shall be used with device type 02 only and shall be such that AV = 5 V/V.
5/ The nulling amplifier shall be a M38510/11001XXX or similar. Saturation of the nulling amplifier is not allowed.
FIGURE 3. Test circuit for channel separation - Continued.
19