TABLE lll. Group A inspection for device type 10 - Continued.
Symbol |
MlL- STD- 883 method |
Cases R, S, and 2 |
Terminal conditions 11 |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
Subgroup 1 TC = +25°C |
Subgroup 2 TC = +125°C |
Subgroup 3 TC = -55°C |
||||||||
Test no. |
1G |
1A |
2A |
3A |
4A |
5A |
6A |
7A |
8A |
GND |
8Y |
7Y |
6Y |
5Y |
4Y |
3Y |
2Y |
1Y |
2G |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
lOZL |
65 66 67 68 69 70 71 72 |
91 " " " " " " " |
91 |
91 |
91 |
91 |
91 |
91 |
91 |
91 |
GND " " " " " " " |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
0.8V " " " " " " " |
6V " " " " " " " |
1Y 2Y 3Y 4Y 5Y 6Y 7Y 8Y |
-0.2 " " " " " " " |
-2.0 " " " " " " " |
µA " " " " " " " |
|||||
llH |
3010 |
73 74 75 76 77 78 79 80 81 82 |
6V GND " " " " " " " " |
GND 6V GND " " " " " " " |
GND " 6V GND " " " " " " |
GND " " 6V GND " " " " " |
GND " " " 6V GND " " " " |
GND " " " " 6V GND " " " |
GND " " " " " 6V GND " " |
GND " " " " " " 6V GND GND |
GND " " " " " " " 6V GND |
" " " " " " " " " " |
GND " " " " " " " " 6V |
6V " " " " " " " " " |
1G 1A 2A 3A 4A 5A 6A 7A 8A 2G |
.05 " " " " " " " " " |
0.1 " " " " " " " " " |
" " " " " " " " " " |
||||||||||||
llL |
3009 |
83 84 85 86 87 88 89 90 91 92 |
GND 6V " " " " " " " " |
6V GND 6V " " " " " " " |
6V " GND 6V " " " " " " |
6V " " GND 6V " " " " " |
6V " " " GND 6V " " " " |
6V " " " " GND 6V " " " |
6V " " " " " GND 6V " " |
6V " " " " " " GND 6V 6V |
6V " " " " " " " GND 6V |
" " " " " " " " " " |
" " " " " " " " " GND |
" " " " " " " " " " |
1G 1A 2A 3A 4A 5A 6A 7A 8A 2G |
-.05 " " " " " " " " " |
-0.1 " " " " " " " " " |
" " " " " " " " " " |
||||||||||||
lOS4 |
3011 |
93 94 95 96 97 98 99 100 |
GND " " " " " " " |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND " " " " " " " |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND " " " " " " " |
4V " " " " " " " |
1Y 2Y 3Y 4Y 5Y 6Y 7Y 8Y |
-10 " " " " " " " |
-135 " " " " " " " |
-10 " " " " " " " |
-135 " " " " " " " |
-10 " " " " " " " |
-135 " " " " " " " |
mA " " " " " " " |
Subgroup 4 TC = +25°C |
||||||||||||||||||||||||||||||
Min |
Max |
|||||||||||||||||||||||||||||
Ci |
3012 |
101 102 103 104 105 106 107 108 109 110 |
21 |
21 |
21 |
21 |
21 |
21 |
21 |
21 |
21 |
GND " " " " " " " " " |
21 |
GND " " " " " " " " " |
1G 1A 2A 3A 4A 5A 6A 7A 8A 2G |
10 " " " " " " " " " |
pF " " " " " " " " " |
|||||||||||||
Co |
3012 |
111 112 |
GND 6V |
" " |
21 |
21 |
21 |
21 |
21 |
21 |
21 |
21 |
6V GND |
6V 6V |
Y's Y's |
20 20 |
" " |
|||||||||||||
Subgroup 7 TC = +25°C |
Subgroup 8 TC = +125°C |
Subgroup 8 TC = -55°C |
||||||||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||||||||
Truth table 61 |
113 114 |
B B |
B A |
B A |
B A |
B A |
B A |
B A |
B A |
B A |
GND " |
H L |
H L |
H L |
H L |
H L |
H L |
H L |
H L |
B B |
4.5V 4.5V |
71 71 |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business