TABLE III. Group A inspection for device type 02 - Continued.
Symbol |
MIL- STD- 883 method |
Case |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||
2 |
2 |
3 |
4 |
6 |
8 |
9 |
10 |
12 |
13 |
14 |
16 |
18 |
19 |
20 |
Subgroup 1 TC = +25°C |
Subgroup 2 TC = +125°C |
Subgroup 3 TC = -55°C |
|||||||
C and D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
||||||||||
Test no. |
1A |
1Y |
2A |
2Y |
3A |
3Y |
GND |
4Y |
4A |
5Y |
5A |
6Y |
6A |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
VH |
51 52 53 54 55 56 |
5/ |
5/ |
5/ |
GND " " " " " |
5/ |
5/ |
5/ |
6V " " " " " |
1Y 2Y 3Y 4Y 5Y 6Y |
0.5 " " " " " |
2.5 " " " " " |
0.5 " " " " " |
2.5 " " " " " |
0.5 " " " " " |
2.5 " " " " " |
V " " " " " |
|||||||
IOS4 |
3011 |
57 58 59 60 61 62 |
GND " " " " " |
GND |
GND " " " " " |
GND |
GND " " " " " |
GND |
" " " " " " |
GND |
GND " " " " " |
GND |
GND " " " " " |
GND |
GND " " " " " |
4V " " " " " |
1Y 2Y 3Y 4Y 5Y 6Y |
-10 " " " " " |
-120 " " " " " |
-10 " " " " " |
-120 " " " " " |
-10 " " " " " |
-120 " " " " " |
mA " " " " " |
IIH |
3010 |
63 64 65 66 67 68 |
6V GND " " " " |
" 6V GND " " " |
" " 6V GND " " |
" " " " " " |
" " " 6V GND GND |
" " " " 6V GND |
" " " " " 6V |
6V " " " " " |
1A 2A 3A 4A 5A 6A |
.05 " " " " " |
0.1 " " " " " |
µA " " " " " |
||||||||||
IIL |
3009 |
69 70 71 72 73 74 |
" 6V " " " " |
6V GND 6V " " " |
6V 6V GND 6V " " |
GND " " " " " |
6V " " GND 6V 6V |
6V " " " GND 6V |
" " " " " GND |
6V " " " " " |
1A 2A 3A 4A 5A 6A |
-.05 " " " " " |
-0.1 " " " " " |
µA " " " " " |
||||||||||
Subgroup 4 TC = +25°C |
||||||||||||||||||||||||
Min |
Max |
|||||||||||||||||||||||
Ci |
3012 |
75 76 77 78 79 80 |
2/ |
2/ |
2/ |
GND " " " " " |
2/ |
2/ |
2/ |
GND " " " " " |
1A 2A 3A 4A 5A 6A |
10 " " " " " |
pF " " " " " |
|||||||||||
Subgroup 9 TC = +25°C |
Subgroup 10 TC = +125°C |
Subgroup 11 TC = -55°C |
||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||
tPHL |
3003 (Fig. 3) |
81 82 83 84 85 86 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
GND " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
4.5V " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
8 " " " " " |
25 " " " " " |
8 " " " " " |
33 " " " " " |
8 " " " " " |
25 " " " " " |
ns " " " " " |
tPHL |
3003 (Fig. 3) |
87 88 89 90 91 92 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
" " " " " " |
" " " " " " |
" " " " " " |
" " " " " " |
" " " " " " |
" " " " " " |
" " " " " " |
See footnotes at end of table.