MlL-M-38510/135G
TABLE lV. Group C end-point and group B, class S, electrical parameters.
VCM = 0, ±VCC = ±15 V for all device types. |
|||||||||
TA = 25°C for Group C end-point limits, -55°C ≤ TA ≤ +125°C for group B, class S, end-point limits. |
|||||||||
Test |
Device 01 |
Device 02 |
Units |
||||||
Limit |
Delta |
Limit |
Delta |
||||||
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
||
VlO |
-135 |
135 |
-75 |
75 |
-300 |
300 |
-100 |
100 |
∝V |
+llB |
-5 |
5 |
-1 |
1 |
-7.5 |
7.5 |
-1.5 |
1.5 |
nA |
-llB |
-5 |
5 |
-1 |
1 |
-7.5 |
7.5 |
-1.5 |
1.5 |
nA |
Test |
Devices 03, 05, and 06 |
Device 04 |
Units |
||||||
Limit |
Delta |
Limit |
Delta |
||||||
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
||
VlO |
-135 |
135 |
-75 |
75 |
-280 |
280 |
-100 |
100 |
∝V |
+llB |
-70 |
70 |
-10 |
10 |
-70 |
70 |
-10 |
10 |
nA |
-llB |
-70 |
70 |
-10 |
10 |
-70 |
70 |
-10 |
10 |
nA |
5. PACKAGlNG
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging requirements are maintained by the lnventory Control Point's packaging activity within the Military Service or Defense Agency, or within the military service's system command. Packaging data retrieval is available from the managing Military Department's or Defense Agency's automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.