TABLE III. Group A inspection for device types 03, 04, 05, and 06 - Continued.
Subgroup |
Symbol |
MIL- STD- 883 method |
Test no. |
Notes 1/ |
Adapter pin number |
Energized relays |
Measured pin |
Equation |
Device type |
Limits |
Unit |
|||||
1 |
2 |
3 |
No. |
Value |
Units |
Min |
Max |
|||||||||
5 TA = +125°C |
�VIO/�T |
4001 |
15 |
See fig. 4 4/ |
�VIO / �T = (E14 - E44)/100(1000) |
03,05,06 04 |
-0.6 -1.0 |
0.6 1.0 |
µV/°C |
|||||||
AVS(+) |
4004 |
51 |
15 |
-15 |
-10 |
K4 |
4 |
E49 |
V |
AVS(+) = 10/(E15 - E49) |
03,04, 05,06 |
600 |
V/mV |
|||
AVS(-) |
4004 |
52 |
15 |
-15 |
10 |
K4 |
4 |
E50 |
V |
AVS(-) = 10/(E50 - E15) |
03,04, 05,06 |
600 |
V/mV |
|||
6 TA = -55°C |
+VOP |
4004 |
53 54 |
15 |
-15 |
-15 |
K7 K4 |
5 |
E51 E52 |
V V |
+VOP = E51 +VOP = E52 |
03,04,06 05 |
10 11.5 |
V " |
||
-VOP |
4004 |
55 56 |
15 |
-15 |
15 |
K7 K4 |
5 |
E53 E54 |
V V |
-VOP = E53 -VOP = E54 |
03,04,06 05 |
-10 -11.5 |
" " |
|||
�VIO/�T |
4001 |
28 |
See fig. 4 4/ |
�VIO / �T = (E26 - E44) / 100(1000) |
03,05,06 04 |
-0.6 -1.0 |
0.6 1.0 |
µV/°C |
||||||||
AVS(+) |
4004 |
57 |
15 |
-15 |
-10 |
K4 |
4 |
E55 |
V |
AVS(+) = 10/(E27 - E55) |
03,04, 05,06 |
600 |
V/mV |
|||
AVS(-) |
4004 |
58 |
15 |
-15 |
10 |
K4 |
4 |
E56 |
V |
AVS(-) = 10/(E56 - E27) |
03,04, 05,06 |
600 |
V/mV |
|||
7 TA = +25°C |
SR(+) |
4002 |
59 |
5/ 6/, 7/ |
15 |
-15 |
0 |
K4,K9, K10 |
5 |
�VO(+), �t(+) |
V / µs |
SR(+) = �VO(+) / �t(+) |
03,04,06 05 |
1.7 11 |
V/µs |
|
SR(-) |
4002 |
60 |
5/ 6/, 7/ |
15 |
-15 |
0 |
K4,K9, K10 |
5 |
�VO(-), �t(-) |
V / µs |
SR(-) = �VO(-) / �t(-) |
03,04,06 05 |
1.7 11 |
V/µs |
||
En |
61 62 63 |
fO = 10 Hz fO = 100 Hz fO = 1 kHz see fig. 6 |
E57 E58 E59 |
nV / Hz |
En = E57 En = E58 En = E59 |
03,05 04 06 03,05 04,06 03,05 04 06 |
5.5 6.0 8 4.0 5.0 3.8 3.9 4 |
nV / Hz |
||||||||
Enpp |
64 |
See fig. 7 |
E60 |
VPP |
Enpp = E60 / 50000 |
03,05 04 06 |
.18 .20 .375 |
µVPP |
||||||||
9 TA = +25°C |
In |
65 66 67 |
fO = 10 Hz fO = 100 Hz fO = 1 kHz see fig. 6 |
E61 E62 E63 |
pA / Hz |
2 2 -15 -10 In = {[(E61) - (E57) - (1.64 x 10 )] 10 } 0.5 2 2 -15 -10 In = {[(E62) - (E58) - (1.64 x 10 )] 10 } 0.5 2 2 -15 -10 In = {[(E63) - (E59) - (1.64 x 10 )] 10 } 0.5 |
03,04,05 06 03,05 04 06 03,05 04 06 |
5.66 35 1.88 2.1 18 0.84 0.89 5 |
pA / Hz |
See footnotes at end of table.