TA8LE lll. Group A inspection - Continued.
Subgroup |
Symbol |
Test no. |
Adapter pin numbers |
Relays energized |
Measured pin |
Equation |
Limits |
Unit |
||||||
5 |
6 |
7 thru 16 |
22 thru 37 |
No. |
value |
Unit |
Min |
Max |
||||||
3 TA = -55°C |
+PSS1 -PSS1 |
203 204 205 |
+4.5 v +5.0 v +5.5 v |
-15 v " " |
1111 1111 11 " " |
0000 0000 0011 1111 " " |
None " " |
19 " " |
E161 E162 E163 |
v " " |
+PSS1 = ((E161-E162)/G1)(9.7656E-3)(10) -PSS1 = ((E163-E162)/G1)(9.7656E-3)(10) |
-0.02 " " |
+0.02 " " |
LS8 /%PS " |
+PSS2 -PSS2 |
206 207 208 |
+13.5 v +15 v +16.5 v |
" " " |
" " " |
" " " |
" " " |
" " " |
E164 E165 E166 |
" " " |
+PSS2 = ((E164-E165)/G1)(9.7656E-3)(10) +PSS2 = ((E166-E165)/G1)(9.7656E-3)(10) |
" " " |
" " " |
" " " |
|
-PSS1 |
209 210 211 |
+5 v " " |
-13.5 v -15 v -16.5 v |
" " " |
" " " |
" " " |
" " " |
E167 E168 E169 |
" " " |
-PSS1 = ((E167-E168)/G1)(9.7656E-3)(10) -PSS1 = ((E169-E168)/G1)(9.7656E-3)(10) |
-0.05 " " |
+0.05 " " |
" " " |
|
-PSS2 |
212 213 214 |
+15 v " " |
-10.8 v -12 v -13.2 v |
" " " |
" " " |
" " " |
" " " |
E170 E171 E172 |
" " " |
-PSS2 = ((E170-E171)/G1)(9.7656E-3)(10) -PSS2 = ((E172-E171)/G1)(9.7656E-3)(10) |
" " " |
" " " |
" " " |
|
LE " " " " " " " " " " " " " " " " " " " " |
215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 |
" " " " " " " " " " " " " " " " " " " " " |
-15 v " " " " " " " " " " " " " " " " " " " " |
0001 0000 00 0010 0000 00 0011 0000 00 0100 0000 00 0101 0000 00 0110 0000 00 0111 0000 00 1000 0000 00 1001 0000 00 1010 0000 00 1011 0000 00 1100 0000 00 1101 0000 00 1110 0000 00 1111 0000 00 0000 0000 01 0000 0000 10 0000 0001 00 0000 0010 00 0000 0100 00 0000 1000 00 |
1110 1111 1111 1111 1101 1111 1111 1111 1100 1111 1111 1111 1011 1111 1111 1111 1010 1111 1111 1111 1001 1111 1111 1111 1000 1111 1111 1111 0111 1111 1111 1111 0110 1111 1111 1111 0101 1111 1111 1111 0100 1111 1111 1111 0011 1111 1111 1111 0010 1111 1111 1111 0001 1111 1111 1111 0000 1111 1111 1111 1111 1111 1011 1111 1111 1111 0111 1111 1111 1110 1111 1111 1111 1101 1111 1111 1111 1011 1111 1111 1111 0111 1111 1111 |
" " " " " " " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " " " " " " |
E173 E174 E175 E176 E177 E178 E179 E180 E181 E182 E183 E184 E185 E186 E187 E188 E189 E190 E191 E192 E193 |
" " " " " " " " " " " " " " " " " " " " " |
For each input code N calculate the corresponding linearity error in LS8. LE = ((EA/G1)+(N)(K)-(vOS))/(9.7656E-3) where EA = measured value E173 through E193 G1 = error amplifier gain from step 192 N = OUT input digital code word in decimal form. Thus for 10 bits N = (A1)(2exp7)+(A2)(2exp6)+… +(A10)(2exp0) A1,A2, … A10 are 0 or 1. K = actual volts/count scale factor. K = (vFS - vOS)/1023 where vFS = value at E159 vOS = value at E160 |
-0.5 " " " " " " " " " " " " " " " " " " " " |
+0.5 " " " " " " " " " " " " " " " " " " " " |
LS8 " " " " " " " " " " " " " " " " " " " " |
|
Subgroup |
Symbol |
Test no. |
Adapter pin numbers |
Relays energized |
Measured pin |
Equation |
Limits |
Unit |
||||||
4 |
5 |
7 thru 16 |
22 thru 37 |
No. |
value |
Unit |
Min |
Max |
||||||
3 TA= -55°C |
MCE1 MCE2 MCE3 MCE4 MCE5 MCE6 MCE7 MCE8 MCE9 MCE10 |
236 237 238 239 240 241 242 243 244 245 |
+15 v " " " " " " " " " " " " " " " " " " " |
-15 v " " " " " " " " " " " " " " " " " " " |
0111 1111 11 1000 0000 00 0011 1111 11 0100 0000 00 0001 1111 11 0010 0000 00 0000 1111 11 0001 0000 00 0000 0111 11 0000 1000 00 0000 0011 11 0000 0100 00 0000 0001 11 0000 0010 00 0000 0000 11 0000 0001 00 0000 0000 01 0000 0000 10 0000 0000 00 0000 0000 01 |
1000 0000 0011 1111 0111 1111 1111 1111 1100 0000 0011 1111 1011 1111 1111 1111 1110 0000 0011 1111 1101 1111 1111 1111 1111 0000 0011 1111 1110 1111 1111 1111 1111 1000 0011 1111 1111 0111 1111 1111 1111 1100 0011 1111 1111 1011 1111 1111 1111 1110 0011 1111 1111 1101 1111 1111 1111 1111 1111 1111 1111 1110 1111 1111 1111 1111 1011 1111 1111 1111 0111 1111 1111 1111 1111 1111 1111 1111 1011 1111 |
None " " " " " " " " " " " " " " " " " " " |
19 " " " " " " " " " " " " " " " " " " " |
E194 E195 E196 E197 E198 E199 E200 E201 E202 E203 E204 E205 E206 E207 E208 E209 E210 E211 E212 E213 |
v " " " " " " " " " " " " " " " " " " " |
For each set of major carry codes N and N+1 calculate the associated error in LS8's as follows: MCE = ((E8-EA)/G1)(9.7656E-3) where E8 = Measured value from E194, E196, E198, etc. EA = Measured value from E195, E197, E199, etc. |
-1 " " " " " " " " " " " " " " " " " " " |
+1 " " " " " " " " " " " " " " " " " " " |
LS8 " " " " " " " " " " " " " " " " " " " |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business