MIL-M-38510/133B
NOTES:
1. Unless otherwise defined, all capacitors are 47 µF tantalum paralleled with 0.1 µF ceramic.
2. Bandwidth of the oscilloscope shall be 50 MHz minimum; saturation of the preamp must be avoided. Use a voltage comparator preamp.
3. Adjust the coarse and fine offset controls to position the waveform final value on the oscilloscope center horizontal graticule.
4. While operating switch S-1, adjust the oscilloscope vertical gain for ½ LSB per cm.
5. 01 = 02 = MP 5082-2835 or equivalent.
6. All grounds must be separately connected to unipoint ground at device pin 1.
Figure 3. Test circuit for settling time.