MIL-M-38510/1338
NOTES:
1. Unless otherwise stated, all capacitors are 47 µF tantalum paralleled with 0.1 µF ceramic.
2. The meter shall be true rms reading with a bandwidth greater than 100 kHz.
3. A1, A2, and A3 shall have a gain-bandwidth product greater than 5 MHz and input noise
density less than 10 nV/ Hz .
4. All "A" point ground connections shall return to a single unipoint ground at device pin 1.
5. With S-1 in position 2, the measured rms noise voltage shall be less than 1.0 mV rms. (NO for all bits off.)
6. With S-1 in position 1, the measured rms noise voltage shall be:
NO for OUT = √ (NO)2 for all bits on - (NO)2 for all bits off
100
Figure 5. Test circuit for noise tests.
12