MIL-M-38510/1258
NOTES:
1. Last component designations are R13, C9, U2, 04, and K8
2. All resistors are ±1 % film unless otherwise stated.
3. U1 offset error shall be measured with pin 9 grounded and the device under test (0.U.T.) removed.
This error shall be removed in the software calculations.
4. Relay control inputs are not shown.
5. A speed-up circuit is required in series with the logic input for rise times greater than 0.5 µs.
6. The adapter S/H U2 is required for TA = 125°C testing of some parameters.
FIGURE 3. Test circuit for static and dynamic tests.
13