MIL-HDBK-780D
w/CHANGE 1
4.2.5.6 Tabular listing of conformance inspection. Where it will lead to better understanding of their functions, the inspections should be listed as group A, B, C, D or E in tabular form with appropriate references to applicable requirements, and inspection methods in MIL-STD-883, MIL-PRF-38534, or MIL-PRF-38535 as illustrated below:
" 4.3 Conformance inspection. Conformance inspection shall be in accordance with method 5005 of
MIL-STD-883 including groups A, B, C, and D inspections. The following additional criteria shall apply.
Test requirements |
Subgroups (in accordance with MIL-STD-883, method 5005, table I) |
Interim electrical parameters |
|
Final electrical test parameters |
|
Group A test requirements |
|
Groups C and D end-point electrical parameters |
"
4.2.6 Section 5.
4.2.6.1 Packaging, packing, and marking. Packaging, packing, and marking should be as specified in the applicable general specification.
4.2.7 Section 6.
4.2.7.1 Notes. Section 6 should contain information of a general or explanatory nature and no requirements should appear therein. It should contain information designed to assist in determining the applicability of the SMD.
4.2.7.2 Intended use. Items conforming to the SMD are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
4.2.7.3 Comments. Comments on the SMD should be directed to the applicable MPCAG.
4.2.7.4 Sources of supply. Sources of supply will be identified in MIL-HDBK-103 (see 4.3) or the appropriate Qualified Manufacturers List (QML). The vendors so listed will have agreed to the SMD and submitted a certificate of compliance (see 4.2.4.11) and completed qualification requirements. Additional sources will be added to these listings as they become available.