TABLE III. Group A inspection for device type 08 - Continued.
Symbol |
MIL-STD- 883 method |
Terminal conditions 11 |
Measured terminal |
Test limits |
Unit |
|||||||||||||||||||||||||||||
Case 3 |
2 |
3 |
4 |
5 |
6 |
7 |
9 |
10 |
11 |
12 |
13 |
14 |
16 |
17 |
18 |
19 |
20 |
21 |
23 |
24 |
25 |
26 |
27 |
28 |
Subgroup 9 TC = +25°C 41 |
Subgroup 10 TC = +125°C |
Subgroup 11 TC = -55°C 41 |
|||||||
Cases L, K |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
||||||||||
Test no. |
CAB |
SAB |
DIR |
A1 |
A2 |
A3 |
A4 |
A5 |
A6 |
A7 |
A8 |
GND |
B8 |
B7 |
B6 |
B5 |
B4 |
B3 |
B2 |
B1 |
G |
SBA |
CBA |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tPHL4 |
3003 (Fig. 3) |
354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 |
GND " " " " " " " 61 " " " " " " " |
GND " " " " " " " IN " " " " " " " |
GND " " " " " " " 4.5V " " " " " " " |
OUT 61 |
OUT 61 |
OUT 61 |
OUT 61 |
OUT 61 |
OUT 61 |
OUT 61 |
OUT 61 |
GND " " " " " " " " " " " " " " " |
61 OUT |
61 OUT |
61 OUT |
61 OUT |
61 OUT |
61 OUT |
61 OUT |
61 OUT |
GND " " " " " " " " " " " " " " " |
IN " " " " " " " GND " " " " " " " |
61 " " " " " " " GND " " " " " " " |
4.5V " " " " " " " " " " " " " " " |
SBA to A1 SBA to A2 SBA to A3 SBA to A4 SBA to A5 SBA to A6 SBA to A7 SBA to A8 SAB to B1 SAB to B2 SAB to B3 SAB to B4 SAB to B5 SAB to B6 SAB to B7 SAB to B8 |
10 " " " " " " " " " " " " " " " |
38 " " " " " " " " " " " " " " " |
10 " " " " " " " " " " " " " " " |
51 " " " " " " " " " " " " " " " |
10 " " " " " " " " " " " " " " " |
38 " " " " " " " " " " " " " " " |
ns " " " " " " " " " " " " " " " |
tPLH4 |
3003 (Fig. 3) |
370 to 385 |
Same terminal conditions and measured terminals as specified above for tPHL4. |
10 |
38 |
10 |
51 |
10 |
38 |
ns |
||||||||||||||||||||||||
tPZH2 |
3003 (Fig. 3) |
386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 |
GND " " " " " " " " " " " " " " " |
GND " " " " " " " " " " " " " " " |
OUT 4.5V |
OUT 4.5V |
OUT 4.5V |
OUT 4.5V |
OUT 4.5V |
OUT 4.5V |
OUT 4.5V |
OUT 4.5V |
GND " " " " " " " " " " " " " " " |
4.5V OUT |
4.5V OUT |
4.5V OUT |
4.5V OUT |
4.5V OUT |
4.5V OUT |
4.5V OUT |
4.5V OUT |
IN " " " " " " " " " " " " " " " |
GND " " " " " " " " " " " " " " " |
4.5V " " " " " " " " " " " " " " " |
G to A1 G to A2 G to A3 G to A4 G to A5 G to A6 G to A7 G to A8 G to B1 G to B2 G to B3 G to B4 G to B5 G to B6 G to B7 G to B8 |
6 " " " " " " " " " " " " " " " |
43 " " " " " " " " " " " " " " " |
6 " " " " " " " " " " " " " " " |
57 " " " " " " " " " " " " " " " |
6 " " " " " " " " " " " " " " " |
43 " " " " " " " " " " " " " " " |
ns " " " " " " " " " " " " " " " |
||
tPZL2 |
3003 (Fig. 3) |
402 to 417 |
Same terminal conditions (except GND replaces 4.5 V) and measured terminals as specified above for tPZH2. |
" |
" |
" |
" |
" |
" |
" |
||||||||||||||||||||||||
tPHZ2 |
3003 (Fig. 3) |
418 to 433 |
Same terminal conditions and measured terminals as specified above for tPZH2. |
" |
" |
" |
" |
" |
" |
" |
||||||||||||||||||||||||
tPLZ2 |
3003 (Fig. 3) |
434 to 449 |
Same terminal conditions and measured terminals as specified above for tPZL2. |
" |
" |
" |
" |
" |
" |
" |
See footnotes at end of table.