TA8LE III. Group A inspection for device type 02 - Continued.
Symbol |
MIL- STD- 883 method |
Case 2 |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||
2 |
3 |
4 |
6 |
8 |
9 |
10 |
12 |
13 |
14 |
16 |
18 |
19 |
20 |
Subgroup 9 TC = +25°C 4/ |
Subgroup 10 TC = +125°C |
Subgroup 11 TC = -55°C 4/ |
||||||||
Cases C, D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
||||||||||
Test no. |
G1 |
NC |
A1 |
A2 |
A3 |
A4 |
GND |
84 |
83 |
82 |
81 |
NC |
G2 |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tPHZ1 |
3003 (Fig. 3) |
134 135 136 137 138 139 140 141 |
IN " " " 4.5V " " " |
4.5V OUT |
4.5V OUT |
4.5V OUT |
4.5V OUT |
GND " " " " " " " |
OUT 4.5V |
OUT 4.5V |
OUT 4.5V |
OUT 4.5V |
GND " " " IN " " " |
4.5V " " " " " " " |
G1 to 81 G1 to 82 G1 to 83 G1 to 84 G2 to A1 G2 to A2 G2 to A3 G2 to A4 |
4 " " " " " " " |
32 " " " " " " " |
4 " " " " " " " |
42 " " " " " " " |
4 " " " " " " " |
32 " " " " " " " |
ns " " " " " " " |
||
tPLZ1 |
3003 (Fig. 3) |
142 143 144 145 146 147 148 149 |
IN " " " 4.5V " " " |
GND OUT |
GND OUT |
GND OUT |
GND OUT |
" " " " " " " " |
OUT GND |
OUT GND |
OUT GND |
OUT GND |
GND " " " IN " " " |
" " " " " " " " |
G1 to 81 G1 to 82 G1 to 83 G1 to 84 G2 to A1 G2 to A2 G2 to A3 G2 to A4 |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |