MIL-M-38510/650C
NOTES:
1. CL = 50 pF ±10%, includes test jig and probe capacitance.
2. Input pulse shall have the following characteristics: tr = tf ≤ 6 ns; PRR ≤ 1MHz; duty cycle = 50%.
3. All unused inputs are tied to VCC.
4. tTHL1 - tTHL2 = tTHL; tTLH2 - tTLH1 = tTLH.
FIGURE 3. Switching time test circuit and waveforms.