GENERATOR CHARACTERISTICS
RL
2
= 50ν ±5%
SCOPE INPUT = 50ν to GND CL (test jig) ≤ 5 pF
FREQ. (OUT) = FREQ (IN)
2
NOTES:
FMAX IS HIGHEST INPUT FREQUENCY AT WHICH DEVICE CEASES TO TOGGLE
1. Perform test in accordance with test table; each output is tested separately.
2. All input and output cables are equal lengths of 50 ohm coaxial cables. Wire length should be ≤ .250
(6.35 mm) from tp in to input pin and tp out to output pin.
3. Outputs not under test connected to a 100 ohm resistor to ground.
4. Note that observed pulse amplitude is attenuated by one half.
FIGURE 10. FMAX test circuit for device type 04.