MIL-M-38510/61C
GENERATOR CHARACTERISTICS
zOUT = 50ν
tP (data) = 40 ns
tP (clock) = 40 ns
PRR = 1 MHz
Device type 01
tTHL = 2.0 ns (20%-80%)
tTLH = 2.0 ns (20%-80%)
Device type 02
tTHL = 1.5 ns (20%-80%)
tTLH = 1.5 ns (20%-80%)
RL
2
= 50ν ±5%
SCOPE INPUT = 50ν to GND CL (test jig) ≤ 5 pF
NOTES:
1. Perform test in accordance with test table; each output is tested separately.
2. All input and output cables are equal lengths of 50 ohm coaxial cables. Wire length should be ≤ .250
(6.35 mm) from tp in to input pin and tp out to output pin.
3. Outputs not under test connected to a 100 ohm resistor to ground.
4. Note that observed pulse amplitude is attenuated by one half.
FIGURE 6. Setup and hold test circuit for device types 01 and 02.