MIL-M-38510/61C
GENERATOR CHARACTERISTICS
zOUT = 50ν
tP (P/S & CLR) = 40 ns
PRR = 1 MHz
Device type 01
tTHL = 2.0 ns (20%-80%)
tTLH = 2.0 ns (20%-80%)
Device type 02
tTHL = 1.5 ns (20%-80%)
tTLH = 1.5 ns (20%-80%)
RL
2
= 50ν ±5%
SCOPE INPUT = 50ν to GND CL (test jig) ≤ 5 pF
NOTES:
1. Perform test in accordance with test table; each output is tested separately.
2. All input and output cables are equal lengths of 50 ohm coaxial cables. Wire length should be ≤ .250
(6.35 mm) from tp in to input pin and tp out to output pin.
3. Outputs not under test connected to a 100 ohm resistor to ground.
4. Note that observed pulse amplitude is attenuated by one half.
FIGURE 4. Preset and clear switching test circuit for device types 01 and 02.
14
Source: https://assist.dla.mil -- Downloaded:
Check the source to verify that this is the current version before use.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business