TABLE III. Group A inspection for device types 01 and 03 - Continued.
Terminal conditions (outputs not designated are open or resistive coupled to GND or voltage;
inputs not designated are z 2.0 V, low s 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases E,F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Test limits |
Unit |
|
Test no. |
01 |
02 |
03 |
04 |
05 |
06 |
07 |
GND |
08 |
A0 |
A1 |
A2 |
A3 |
A4 |
CE |
VCC |
Min |
Max |
|||||
7 TC = 25°C |
Func- tional test |
6/ " " " " " " " |
36 " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
GND " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
6/ " " " " " " " |
01 02 03 04 05 06 07 08 |
6/ " " " " " " " |
||
8 |
Same tests, terminal conditions, and limits as for subgroup 7, except TC = 125°C and -55°C. |
||||||||||||||||||||||
9 TC = 25°C |
tPHL1 |
GALPAT Fig. 4 |
37 |
7/ |
7/ |
7/ |
7/ |
7/ |
7/ |
7/ |
GND |
7/ |
8/ |
8/ |
8/ |
8/ |
8/ |
GND |
8/ |
0utputs |
9/ |
ns |
|
tPLH1 |
GALPAT Fig. 4 |
38 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
8/ |
8/ |
8/ |
8/ |
8/ |
GND |
8/ |
" |
9/ |
" |
||
tPHL2 |
Sequen- tial Fig. 4 |
39 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
10/ |
10/ |
10/ |
10/ |
10/ |
10/ |
10/ |
" |
9/ |
" |
||
tPLH2 |
Sequen- tial Fig. 4 |
40 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
10/ |
10/ |
10/ |
10/ |
10/ |
10/ |
10/ |
" |
9/ |
" |
||
10 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = 125°C. |
||||||||||||||||||||||
11 |
Same tests, terminal conditions, and limits as for subgroup 9, except TC = -55°C. |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business