TA8LE III. Group A inspection for device type 05 - Continued.
Terminal conditions (pins not designated may be high � 2.4 V, low s 0.4 V, or open)
1/ In transition from high level to low level.
2/ RXCX connected to VCC through a 5 kn resistor.
3/ In transition from low level to high level.
4/ One high logic level pulse.
5/ One low logic level pulse.
6/ Output voltages for subgroups 7 and 8: H > 1.5 V, L > 1.5 V.
7/ Device must be triggered before tPLH3 and tPHL3 can be measured (see figure 9).
8/ This test shall be performed for bench setup only.
9/ This test shall be performed for automatic test equipment only.
10/ CX connected to RXCX through a 15 pF capacitor which includes stray, probe, and jig capacitance.
11/ CX connected to RXCX through a 1,000 pF capacitor.
12/ RXCX connected to VCC through a 10 kn resistor.