TABLE III. Group A inspection for device type 03 - Continued.
Terminal conditions (pins not designated may be high � 2.4 V, low s 0.4 V, or open)
Subgroup |
Symbol |
MIL-STD- 883 method |
Case E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Test no. |
A1 |
B1 |
Clear 1 |
Q 1 |
Q2 |
CX2 |
RXCX2 |
GND |
A2 |
B2 |
Clear 2 |
Q 2 |
Q1 |
CX1 |
RXCX1 |
VCC |
Min |
Max |
|||||
10 Tc = +125°C |
tW(MIN) 13/ tW(MIN) 13/ tW(MIN) 14/ tW(MIN) 14/ |
3003 (Fig. 7) " " " |
74 75 76 77 |
IN IN |
5.0 V 5.0 V |
5.0 V 5.0 V |
OUT OUT |
11/ |
1/ 1/ |
GND " " " |
IN IN |
5.0 V 5.0 V |
5.0 V 5.0 V |
OUT OUT |
11/ |
1/ 1/ |
5.0 V " " " |
Q1 Q2 Q1 Q2 |
35 35 35 35 |
75 75 105 105 |
ns " " " |
||
tW " |
" " |
78 79 |
GND |
IN |
5.0 V |
OUT |
9/ |
9/ 10/ |
" " |
GND |
IN |
5.0 V |
OUT |
9/ |
9/ 10/ |
" " |
Q1 Q2 |
2.60 2.60 |
4.15 4.15 |
µs " |
|||
11 |
Same tests, terminal conditions and limits as subgroup 10, except TC = -55°C. |
1/ RXCX connected to VCC through a 5 kn resistor.
2/ CX connected to GND or 0.8 V.
3/ For schematic circuits A, B, and C, the minimum and maximum limits shall be -1.4 mA and -0.2 mA, respectively. For schematic circuit D, the minimum and maximum limits shall be -0.7 mA and -1.4 mA, respectively.
4/ In transition from low level to high level.
5/ In transition from high level to low level.
6/ One low logic level pulse. At manufacturer's option, this may be verified in subgroups 9, 10, 11.
7/ Output voltages for subgroups 7 and 8: H > 1.5 V, L > 1.5 V.
8/ One high logic level pulse. At manufacturer's option, this may be verified in subgroups 9, 10, 11.
9/ CX connected to RXCX through a 1,000 pF capacitor.
10/ RXCX connected to VCC through a 10 kn resistor.
11/ Device must be triggered before tPLH3 and tPHL3 can be measured (see figure 7).
12/ CX connected to RXCX through a 15 pF capacitor which includes stray, probe, and jig capacitance.
13/ This test shall be performed for bench setup only.
14/ This test shall be performed for automatic test equipment only.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business