TA8LE III. Group A inspection for device type 02 - Continued.
Terminal conditions (pins not designated may be high � 2.4 V, low s 0.4 V, or open)
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,8,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Test no. |
A1 |
A2 |
81 |
82 |
Clear |
Q |
GND |
Q |
RI |
NC |
CX |
NC |
RXCX |
VCC |
Min |
Max |
|||||
9 Tc = +25°C |
tPLH1 tPLH2 tPLH3 |
3003 (Fig. 6) " |
42 43 44 |
IN OUT 91 |
5.0 V GND 5.0 V |
5.0 V IN 5.0 V |
5.0 V " " |
5.0 V 5.0 V IN |
OUT |
GND " " |
OUT OUT |
71 " " |
71 81 " " |
5.0 V " " |
A1 to Q 81 to Q Clear to Q |
7 7 7 |
37 32 43 |
ns " " |
|||
tPHL1 tPHL2 tPHL3 |
" " " |
45 46 47 |
IN OUT 91 |
5.0 V GND 5.0 V |
5.0 V IN 5.0 V |
" " " |
5.0 V 5.0 V IN |
OUT OUT |
" " " |
OUT |
" " " |
" " " |
" " " |
A1 to Q 81 to Q Clear to Q |
7 7 7 |
43 40 30 |
ns " " |
||||
tW(MIN) 111 |
" |
48 |
IN |
" |
" |
" |
5.0 V |
" |
" |
11 |
" |
Q |
65 |
" |
|||||||
tW(MIN) 121 |
" |
49 |
IN |
" |
" |
" |
" |
" |
" |
101 |
101 11 |
" |
Q |
95 |
" |
||||||
tW |
" |
50 |
GND |
GND |
IN |
" |
" |
" |
" |
71 |
71 81 |
" |
Q |
3.08 |
4.0 |
µs |
|||||
10 Tc = +125°C |
tPLH1 tPLH2 tPLH3 |
3003 (Fig. 6) " |
51 52 53 |
IN GND 91 |
5.0 V GND 5.0 V |
5.0 V IN 5.0 V |
5.0 V " " |
" " IN |
OUT |
GND " " |
" " " |
71 " " |
71 81 " " |
5.0 V " " |
A1 to Q 81 to Q Clear to Q |
7 7 7 |
48 41 56 |
ns " " |
|||
tPHL1 tPHL2 tPHL3 |
" " " |
54 55 56 |
IN GND 91 |
5.0 V GND 5.0 V |
5.0 V IN 5.0 V |
" " " |
5.0 V 5.0 V IN |
OUT OUT |
" " " |
OUT |
" " " |
" " " |
" " " |
A1 to Q 81 to Q Clear to Q |
7 7 7 |
56 51 39 |
" " " |
||||
tW(MIN) 111 |
" |
57 |
IN |
" |
" |
" |
5.0 V |
" |
" |
11 |
" |
Q |
75 |
" |
|||||||
tW(MIN) 121 |
" |
58 |
IN |
" |
" |
" |
" |
" |
" |
101 |
101 11 |
" |
Q |
105 |
" |
||||||
tW |
" |
59 |
GND |
GND |
IN |
" |
" |
" |
" |
71 |
71 81 |
" |
Q |
2.60 |
4.15 |
µs |
|||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
11 RXCX connected to VCC through a 5 kn resistor.
21 In transition from low level to high level.
31 In transition from high level to low level
41 One low logic level pulse.
51 One high logic level pulse
61 Output voltages fro subgroups 7 and 8: H > 1.5 V, L < 1.5 V.
71 CX connected to RXCX through an 1,000 pF capacitor.
81 RXCX connected to VCC through a 10 kn resistor.
91 Device must be triggered before tPHL3 can be measured (see figure 6).
101 CX connected to RXCX through an 15 pF capacitor which includes stray, probe, and jig capacitor.
111 This test shall be performed for bench setup only. For class 8 devices only, this test does not have to be performed at final electricals for subgroup 9. For Group A, subgroup 9 and Group C, subgroups 10 and 11, sample size for these tests shall be 15 devices.
121 This test shall be performed with automatic test equipment only or bench setup. For class 8 devices only, this test does not have to be performed at final electricals for subgroup 9. For Group A, subgroup 9 and
Group C, subgroups 10 and 11, sample size for these tests shall be 15 devices.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744