MIL-M-38510/101K
See notes on page 30
Parameter |
Pulse generator |
Measure |
Equation |
Units |
Rise time (tr) |
+50 mV amplitude |
t (ns), see waveform 1 |
tr = t |
ns |
Overshoot (OS) |
+50 mV amplitude |
�V (mV), see waveform 1 |
OS = (�V / 50) x 100 |
% |
Bandwidth (BW) |
+50 mV amplitude |
Calculate |
3 BW = (0.35 x 10 ) / tr (ns) |
MHz |
Slew rate (+SR) |
-5 V to +5 V step |
�VO (+) (volts), �t (+) (ns) see waveform 2 |
-3 +SR = I�VO(+) / �t(+) x 10 I |
V/µs |
Slew rate (-SR) |
+5 V to -5 V step |
�VO (-) (volts), �t (-) (ns) see waveform 3 |
-3 -SR = I�VO(-) / �t(-) x 10 I |
V/µs |
Settling time tS(+) 5/ |
-5 V to +5 V step |
tS(+), see waveform 2 |
tS(+) = tS(+) |
ns |
Settling time tS(-) 5/ |
+5 V to -5 V step |
tS(-), see waveform 3 |
tS(-) = tS(-) |
ns |
FIGURE 4. Transient response test circuit - Continued.