Parameter |
Apply (in volts) |
Switch position |
Measure |
Measured parameter 20/ |
Units |
||||||||
+VCC |
-VCC |
V |
S1 |
S2 |
S3 |
S4 |
S5 |
S6 |
Value |
Units |
Equation |
||
+IOS (output) |
15 |
-15 |
-15 |
1 |
1 |
1 |
1 |
1 |
2 |
IOS1 |
mA |
+IOS -= IOS1 |
mA |
-IOS (output) |
15 |
-15 |
+15 |
1 |
1 |
1 |
1 |
1 |
2 |
IOS2 |
mA |
-IOS = IOS2 |
mA |
ICC |
15 |
-15 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
ICC |
mA |
ICC = ICC |
mA |
+VOP RL = 10 kn |
20 |
-20 |
-20 |
1 |
1 |
1 |
1 |
2 |
1 |
(E0)1 |
V |
+VOP = (E0)1 |
V |
-VOP RL = 10 kn |
20 |
-20 |
+20 |
1 |
1 |
1 |
1 |
2 |
1 |
(E0)2 |
V |
-VOP = (E0)2 |
V |
+VOP RL = 2 kn |
20 |
-20 |
-20 |
1 |
1 |
1 |
1 |
3 |
1 |
(E0)3 |
V |
+VOP = (E0)3 |
V |
-VOP RL = 2 kn |
20 |
-20 |
+20 |
1 |
1 |
1 |
1 |
3 |
1 |
(E0)4 |
V |
-VOP = (E0)4 |
V |
+AVS 16/ RL = 2 kn |
20 |
-20 |
-15 |
1 |
1 |
1 |
1 |
3 |
1 |
E24 |
V |
+AVS = 15 / (E3 - E24) |
V/mV |
-AVS 16/ RL = 2 kn |
20 |
-20 |
+15 |
1 |
1 |
1 |
1 |
3 |
1 |
E25 |
V |
-AVS = 15 / (E25 - E3) |
V/mV |
AVS 16/ RL = 2 kn |
5 5 |
-5 -5 |
-2 +2 |
1 1 |
1 1 |
1 1 |
1 1 |
3 3 |
1 1 |
E26 E27 |
V |
AVS = 4 / (E27 - E26) |
V/mV |
+AVS 16/ RL = 10 kn |
20 |
-20 |
-15 |
1 |
1 |
1 |
1 |
2 |
1 |
E30 |
V |
+AVS = 15 / (E3 - E30) |
V/mV |
-AVS 16/ RL = 10 kn |
20 |
-20 |
+15 |
1 |
1 |
1 |
1 |
2 |
1 |
E31 |
V |
-AVS = 15 / (E31 - E3) |
V/mV |
AVS 16/ RL = 10 kn |
5 5 |
-5 -5 |
-2 +2 |
1 1 |
1 1 |
1 1 |
1 1 |
2 2 |
1 1 |
E32 E33 |
V |
AVS = 4 / (E33 - E32) |
V/mV |
CMR 3/ |
20 20 |
-20 -20 |
+15 -15 |
2 2 |
1 1 |
1 1 |
1 1 |
1 1 |
1 1 |
E28 1/ E29 1/ |
V |
3 CMR = 20 log 1(30 x 10 ) / (E28 - E29)1 |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business