MIL-M-38510/763B
Device types 02 and 04
MR or SR 1/ |
PE |
CET |
CEP |
Action on rising clock edge (t) |
L |
x |
x |
x |
Reset (clear) 2/ |
H |
L |
x |
x |
Load (Pn to Qn) 2/ |
H |
H |
H |
H |
Count (Increment) 2/ |
H |
H |
L |
x |
No change (Hold) 2/ |
H |
H |
x |
L |
No change (Hold) 2/ |
1/ MR and SR apply to device types 02 and 04, respectively. When MR = L, the device outputs are reset independent of the clock. A reset operation supercedes any other device operation, including the
"no change" operation.
2/ The functionality of the TC output shall satisfy the following Boolean Logic equation,
TC = CET.Q0.Q1.Q2.Q3. For hold and asynchronous reset operations, the functionality of TC is independent of the clock.
Device type 05
Mode select table
PL |
CE |
U/D |
CP |
Mode |
H |
L |
L |
t |
Count up 1/ |
H |
L |
H |
t |
Count down 1/ |
L |
x |
x |
x |
Preset (asynchronous) 1/ |
H |
H |
x |
x |
No change (hold) 1/ |
1/ The fu nctionality of the TC output shall satisfy the following Boolean Logic equation, TC = (U/D.Q0.Q1.Q2.Q3) + (U/D.Q0.Q1.Q2.Q3)
Device type 05
RC truth table
PL |
CE |
TC 1/ |
CP |
RC |
||
H |
L |
H |
|
|||
H |
H |
x |
x |
H |
||
H |
x |
L |
x |
H |
||
L |
x |
x |
x |
H |
1/ TC is generated internally.
= Low clock pulse H = High voltage level L = Low voltage level x = Irrelevant
t = Transition from low-to-high voltage level
FIGURE 2. Truth tables.
15
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.