MIL-M-38510/7638
Device types |
02 |
04 |
05 |
|||
Case outlines |
E, F, Z |
2 |
E, F |
2 |
E, F |
2 |
Terminal number |
Terminal symbol |
|||||
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 |
MR CP P0 P1 P2 P3 CEP GND PE CET Q3 Q2 Q1 Q0 TC vCC - - - - - - - - - - - - |
NC MR CP P0 P1 NC P2 P3 CEP GND NC PE CET Q3 Q2 NC Q1 Q0 TC vCC |
SR CP P0 P1 P2 P3 CEP GND PE CET Q3 Q2 Q1 Q0 TC vCC - - - - - - - - - - - - |
NC SR CP P0 P1 NC P2 P3 CEP GND NC PE CET Q3 Q2 NC Q1 Q0 TC vCC |
P1 Q1 Q0 CE U/D Q2 Q3 GND P3 P2 PL TC RC CP P0 vCC - - - - - - - - - - - - |
NC P1 Q1 Q0 CE NC U/D Q2 Q3 GND NC P3 P2 PL TC NC RC CP P0 vCC |
NC = No connection
Terminal symbol |
Description |
Applicable device type |
MR |
Asynchronous master reset input |
02 |
CP |
Clock pulse input (timing input) |
02, 04, 05 |
CEP |
Count enable parallel input |
02, 04 |
CET |
Count enable trickle input |
02, 04 |
P0-P3 |
Parallel data inputs |
02, 04, 05 |
PE |
Parallel enable inputs |
02, 04 |
Q0-Q3 |
Flip-flop outputs |
02, 04, 05 |
CE |
Count enable input |
05 |
PL |
Asynchronous parallel load input |
05 |
U/D |
Up/down count control input |
05 |
RC |
Ripple clock output |
05 |
TC |
Terminal count output |
02, 04, 05 |
SR |
Synchronous reset input |
04 |
FIGURE 1. Terminal connections.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business