TA8LE III. Group A inspection for device type 03 - Continued.
Symbol |
MIL- STD- 883 method |
Case |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
2 |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
Subgroup 9 TC = +25°C 5/ |
Subgroup 10 TC = +125°C |
Subgroup 11 TC = -55°C 5/ |
|||||||
E and F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
||||||||||
Test no. |
G1 |
A1 |
81 |
1Y0 |
1Y1 |
1Y2 |
1Y3 |
GND |
2Y3 |
2Y2 |
2Y1 |
2Y0 |
82 |
A2 |
G2 |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tTHL |
3003 (Fig. 4) |
128 129 130 131 132 133 134 135 |
IN " " " GND " " " |
GND 4.5V GND 4.5V GND " " " |
GND " 4.5V 4.5V GND " " " |
GND " " " " " " " |
GND " " " " " 4.5V 4.5V |
GND " " " GND 4.5V GND 4.5V |
GND " " " IN " " " |
4.5V " " " " " " " |
1Y0 1Y1 1Y2 1Y3 2Y0 2Y1 2Y2 2Y3 |
3 " " " " " " " |
15 " " " " " " " |
3 " " " " " " " |
20 " " " " " " " |
3 " " " " " " " |
15 " " " " " " " |
ns " " " " " " " |
||||||||
tTLH |
3003 (Fig. 4) |
136 137 138 139 140 141 142 143 |
IN " " " GND " " " |
" 4.5V GND 4.5V GND " " " |
" " 4.5V 4.5V GND " " " |
" " " " " " " " |
GND " " " " " 4.5V 4.5V |
GND " " " GND 4.5V GND 4.5V |
GND " " " IN " " " |
" " " " " " " " |
1Y0 1Y1 1Y2 1Y3 2Y0 2Y1 2Y2 2Y3 |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
See footnotes at end of table.