MIL-M-38510/658A
NOTES:
1. Pulse generator has the following characteristics: tr = tf s 6 ns; PRR s 1 MHz;
duty cycle = 50%.
2. CL = 50 pF ± 10%; includes probe and jig capacitance.
3. Load circuit is applied separately to each output pin under test. All other outputs may be open or loaded.
FIGURE 4. Switching time test circuits and waveforms - Continued.