TABLE III. Group A inspection for device type 01 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E, F, z |
Terminal conditions 61 |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
Subgroup 9 TA = 25°C |
Subgroup 10 TA = 125°C |
Subgroup 11 TA = -55°C |
||||||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
|||||||||||
Test No. |
04 |
02 |
00 |
07 |
09 |
05 |
06 |
VSS |
08 |
A |
D |
C |
B |
01 |
03 |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tTLH 71 " " " " " " " " |
3004 (Fig.4) " " " " " " " " |
143 144 145 146 147 148 149 150 151 152 |
0UT |
0UT |
0UT |
0UT |
0UT |
0UT |
0UT |
GND " " " " " " " " " |
0UT |
A B GND B GND B GND B GND B |
GND " " " " " " " B B |
GND " " " B " " " GND " |
GND " B B GND GND B B GND " |
0UT |
0UT |
5.0V " " " " " " " " " |
A to 00 A to 01 B to 02 B to 03 C to 04 C to 05 B to 06 B to 07 D to 08 D to 09 |
13 " " " " " " " " " |
260 " " " " " " " " " |
18 " " " " " " " " " |
360 " " " " " " " " " |
13 " " " " " " " " " |
260 " " " " " " " " " |
" " " " " " " " " " |
tTHL 71 " " |
" " " |
153 154 155 |
0UT |
0UT |
" " " |
C C GND |
GND GND GND |
" " " |
" " C |
0UT |
" " " |
A to 00 A to 01 B to 02 |
" " " |
" " " |
" " " |
" " " |
" " " |
" " " |
" " " |
|||||||
" " " " " " " |
" " " " " " " |
156 157 158 159 160 161 162 |
0UT |
0UT |
0UT |
0UT |
0UT |
GND " " " " " " |
0UT |
C GND C GND C GND C |
GND " " " " C C |
GND C " " " GND GND |
C GND GND C C GND GND |
0UT |
5.0V " " " " " " |
B to 03 C to 04 C to 05 B to 06 B to 07 D to 08 D to 09 |
" " " " " " " |
" " " " " " " |
" " " " " " " |
" " " " " " " |
" " " " " " " |
" " " " " " " |
ns " " " " " " |
11 The input conditions: VIH = 3.8 V, VIL = 1.1 V at 25°C; VIH = 3.6 V, VIL = 0.85 V at 125°C; VIH = 3.95 V, VIL = 1.35 V at -55°C.
21 The input conditions: VIH = 9.5 V, VIL = 2.8 V at 25°C; VIH = 9.25 V, VIL = 2.55 V at 125°C; VIH = 9.75 V, VIL = 3.05 V at -55°C.
31 See 4.4.1c.
41 The truth table tests shall be performed in sequence.
51 The truth table tests shall be performed with VIH and VDD ≤ 5.0 V and � 15.0 V. L = VSS + 0.5 V maximum and H = VDD - 0.5 V minimum.
61 Pins not designated may be "high" level logic, "low" level logic, or open. Exceptions are as follows: For VIC(P0S) tests, the VSS terminal
shall be open; for VIC(NEG) tests, the VDD terminal shall be open; for ISS tests, the output terminals shall be open.
71 Input conditions A, B, and C refer to the waveforms of figure 4.
81 The device manufacturer may, at his option, measure IIL and IIH at 25°C for each individual input or measure all inputs together.