TABLE III. Group A inspection for device type 01 - Continued.
Symbol |
MIL- STD- 883 method |
Cases E, F, Z |
Terminal conditions 61 |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||
Subgroup 1 TA = 25°C |
Subgroup 2 TA = 125°C |
Subgroup 3 TA = -55°C |
||||||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
|||||||||||
Test No. |
04 |
02 |
00 |
07 |
09 |
05 |
06 |
VSS |
08 |
A |
D |
C |
B |
01 |
03 |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
||||
I0L1 " " " " " " " " " |
11 " " " " " " " " " |
89 90 91 92 93 94 95 96 97 98 |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
GND " " " " " " " " " |
0.5V |
VIL VIH VIL VIH VIL VIH VIL VIH VIL VIH |
VIL " " " " " " " VIH VIH |
VIL " " " VIH " " " VIL " |
VIL " VIH VIH VIL VIL VIH VIH VIL " |
0.5V |
0.5V |
5.0V " " " " " " " " " |
01 02 03 04 05 06 07 08 09 00 |
700 " " " " " " " " " |
900 " " " " " " " " " |
700 " " " " " " " " " |
µA " " " " " " " " " |
|||
I0L2 " " " " " " |
" " " " " " " |
99 100 101 102 103 104 105 |
0.5V |
0.5V |
0.5V |
0.5V |
0.5V |
" " " " " " " |
VIL VIH VIL VIH VIL VIH VIL |
VIL " " " " " " |
" " " " VIH VIH VIH |
" " VIH VIH VIL VIL VIH |
0.5V |
0.5V |
5.5V " " " " " " |
01 02 03 04 05 06 07 |
800 " " " " " " |
1000 " " " " " " |
800 " " " " " " |
" " " " " " " |
||||||
" " " |
" " " |
106 107 108 |
0.5V |
0.5V |
GND GND GND |
0.5V |
VIH VIL VIH |
VIL VIH VIH |
VIH VIL VIL |
VIH VIL VIL |
5.5V 5.5V 5.5V |
08 09 00 |
800 800 800 |
1000 1000 1000 |
800 800 800 |
µA µA µA |
||||||||||
Subgroup 4 TA = 25°C |
||||||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||||
Ci " " " |
3012 " " " |
109 110 111 112 |
GND " " " |
31 |
31 |
31 |
31 |
GND " " " |
A D C B |
12.0 " " " |
pF " " " |
See footnotes at end of device type 01.