TABLE III. Group A inspection for device type 01 - Continued.
Symbol |
MIL- STD- 883 method |
Cases A, C,D,X,Y |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Subgroup 4 TC = 25°C |
||||||||||
Test no. |
IA |
OA |
OB |
IB |
CB |
CC |
VSS |
IC |
OC |
OD |
ID |
CD |
CA |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
||||
CC |
3012 " " " |
92 93 94 95 |
10/ |
10/ |
GND " " " |
10/ |
10/ |
GND " " " |
CB CC CD CA |
12 " " " |
pF " " " |
|||||||||||||
Cis |
3012 " " " |
96 97 98 99 |
10/ |
10/ |
GND " " " |
GND " " " |
GND " " " |
10/ |
10/ |
GND " " " |
GND " " " |
5.0V " " " |
IA IB IC ID |
20 " " " |
" " " " |
|||||||||
Cos |
" " " " |
100 101 102 103 |
11/ |
11/ |
" " " " |
" " " " |
" " " " |
11/ |
11/ |
" " " " |
" " " " |
" " " " |
OA OB OC OD |
15 " " " |
" " " " |
|||||||||
Cios |
" " " " |
104 105 106 107 |
12/ |
12/ |
12/ |
12/ |
" " " " |
" " " " |
" " " " |
12/ |
12/ |
12/ |
12/ |
" " " " |
" " " " |
" " " " |
IA, OA IB, OB IC, OC ID, OD |
20 " " " |
" " " " |
|||||
Subgroup 9 TC = 25°C |
Subgroup 10 TC = 125°C |
Subgroup 11 TC = -55°C |
||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||
tPLH |
3003 Fig. 3 " " |
108 109 110 111 |
IN |
OUT |
OUT |
IN |
GND 5.0V GND " |
GND " 5.0V GND |
GND " " " |
IN |
OUT |
OUT |
IN |
GND " " 5.0V |
5.0V GND " " |
5.0V " " " |
IA to OA IB to OB IC to OC ID to OD |
4 " " " |
125 " " " |
7 " " " |
130 " " " |
4 " " " |
114 " " " |
ns " " " |
tPHL |
" " " " |
112 113 114 115 |
IN |
OUT |
OUT |
IN |
" 5.0V GND " |
" " 5.0V GND |
" " " " |
IN |
OUT |
OUT |
IN |
GND " " 5.0V |
5.0V GND " " |
" " " " |
IA to OA IB to OB IC to OC ID to OD |
" " " " |
130 " " " |
" " " " |
156 " " " |
" " " " |
130 " " " |
" " " " |
tPHZ |
Fig. 4 " " " |
116 117 118 119 |
5.0V |
OUT |
OUT |
5.0V |
" IN GND " |
" " IN GND |
" " " " |
5.0V |
OUT |
OUT |
5.0V |
GND " " IN |
IN GND " " |
" " " " |
CA to OA CB to OB CC to OC CD to OD |
" " " " |
70 " " " |
" " " " |
90 " " " |
" " " " |
50 " " " |
" " " " |
tPZH |
Fig. 4 " " " |
120 121 122 123 |
5.0V |
OUT |
OUT |
5.0V |
" IN GND " |
" " IN GND |
" " " " |
5.0V |
OUT |
OUT |
5.0V |
GND " " IN |
IN GND " " |
" " " " |
CA to OA CB to OB CC to OC CD to OD |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
tPLZ |
Fig. 4 " " " |
124 125 126 127 |
GND |
OUT |
OUT |
GND |
" IN GND " |
" " IN GND |
" " " " |
GND |
OUT |
OUT |
GND |
GND " " IN |
IN GND " " |
" " " " |
CA to OA CB to OB CC to OC CD to OD |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
tPZL |
Fig. 4 " " " |
128 129 130 131 |
GND |
OUT |
OUT |
GND |
" IN GND " |
" " IN GND |
" " " " |
GND |
OUT |
OUT |
GND |
GND " " IN |
IN GND " " |
" " " " |
CA to OA CB to OB CC to OC CD to OD |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
" " " " |
See footnotes at end of device type 02.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business