4. VERIFICATION
MIL-M-38510/58D
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38535 and shall be conducted on all devices prior to qualification and conformance inspection. The following additional criteria shall apply:
a. The burn-in test duration, test condition, and test temperature, or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under document control by the device manufacturer's Technology Review Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1015 of MIL-STD-883.
b. Delete the sequence specified as interim (pre-burn-in) electrical parameters through interim (post-burn-in)
electrical parameters of table IA of MIL-PRF-38535 and substitute lines 1 through 7 of table II herein. c. Burn-in (method 1015 of MIL-STD-883).
(1) Unless otherwise specified in the manufacturers QM plan for static tests (test condition A), ambient temperature (TA) shall be +125°C minimum. Test duration for each static test shall be
24 hours minimum for class S devices and in accordance with table I of method 1015 for class
B devices.
i. For static burn-in I, all inputs shall be connected to 0.0 V. ii. For static burn-in II, all inputs shall be connected to VDD.
iii. Except for VDD and VSS, the terminal shall be connected through resistors whose value is
2 kn to 47 kn. The actual measured value of the resistor selected shall not exceed
±20% of its branded value due to use, heat or age. iv. Output may be open or connected to VDD/2.
v. VDD = 12.5 V minimum, 15 V maximum for device types 01and 02.
VDD = 15 V minimum, 18 V maximum for device types 51 and 52.
VDD/2 = VDD/2 ±1.0 V for all devices. VSS = 0.0 V.
(2) Unless otherwise specified in the manufacturers QM plan for dynamic test (test condition D), ambient temperature shall be +125°C minimum. Test duration shall be in accordance with table I of method 1015.
i. Except for VDD and VSS, the terminals shall be connected through resistors whose value is 2 kn to 47 kn. The actual measured value of the resistor selected shall not exceed
±20% of its branded value due to use, heat or age.
ii. Input signal requirements: Square wave, 50% duty cycle; 25 kHz < PRR < 1 MHz; tTLH
and tTHL < 1 µs. Voltage level: Minimum = VSS - 0.5 V, +10% VDD; Maximum = VDD + 0.5 V, -10% VDD.
iii. VDD = 12.5 V minimum, 15 V maximum for device types 01 and 02.
VDD = 15 V minimum, 18 V maximum for device types 51 and 52.
VDD/2 = VDD/2 ±1.0 V for all devices. VSS = 0.0 V.
15
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business